Dell PowerEdge T410 Hardware Owner's Manual - Page 35
SAS cable - hard drive
View all Dell PowerEdge T410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1810 Hard drive ## The specified hard drive fault. Review has experienced a fault. & clear SEL. See "Troubleshooting a Hard Drive" on page 167. E1812 Hard drive ## The specified hard drive removed. Check has been removed from drive. the system. Information only. E1920 iDRAC6 Upgrade The iDRAC6 Express card Reseat the iDRAC6 Failed is not installed properly or Express Card. See the card is bad. "Installing an iDRAC6 Express Card" on page 127. If the problem persists, see "Getting Help" on page 185. E1A14 SAS cable A SAS cable A is missing or Reseat the cable. If the failure. Check bad. problem persists, replace connection. cable. If the problem persists, see "Getting Help" on page 185. E1A15 SAS cable B SAS cable B is missing or Reseat the cable. If the failure. Check bad. problem persists, replace connection. cable. If the problem persists, see "Getting Help" on page 185. E1A1D Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 185. About Your System 35