Dell PowerEdge T430 Dell PowerEdge T430 Owners Manual - Page 176
°C to 65 °C -40 °F to 149 °F, Temperature Continuous Operation
View all Dell PowerEdge T430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 176 highlights
Expanded Operating Temperature • Non-redundant power supplies are not supported. • Cabled power supply units are not supported. • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Maximum Temperature Gradient (Operating and 20 °C/h (36 °F/h) Storage) Storage Temperature Limits -40 °C to 65 °C (-40 °F to 149 °F) Relative Humidity Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. Temperature (Continuous Operation) Temperature Ranges (for altitude less than 950 m 10 °C to 35 °C (50 °F to 95 °F) with no direct or 3117 ft) sunlight on the equipment. Humidity Percentage Range 10% to 80% Relative Humidity with 29 °C (84.2 °F) maximum dew point. Maximum Vibration Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). Maximum Shock Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Maximum Altitude Operating 3,048 m (10,000 ft) Storage 12,000 m (39,370 ft). 176