If status is Storage Server Overloaded, If these statuses recur, Repairing a storage system

Page 184 highlights

2. Check the Status line on the Details tab. 1. Status line Figure 65 Checking the storage system status on the Details tab . If status is Storage Server Overloaded Wait up to 10 minutes and check the status again. The status may return to Normal and the storage system will be resyncing. If status is Storage Server Inoperable Reboot the storage system and see if it returns to Normal, when it comes back up. If these statuses recur This may be an indication that the underlying hardware problem still exists. Repairing a storage system Repairing a storage system allows you to replace a failed disk in a storage system that contains volumes configured for data protection levels other than Network RAID-0, and trigger only one resync of the data, rather than a complete restriping. Resyncing the data is a shorter operation than a restripe. Prerequisites • Volume must have Network RAID-10, Network RAID-10+1, Network RAID-10+2, Network RAID5, or Network RAID-6. • Storage system must have the blinking red and yellow triangle in the navigation window. 184 Working with clusters

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350

2.
Check the Status line on the Details tab.
1. Status line
Figure 65 Checking the storage system status on the Details tab
.
If status is Storage Server Overloaded
Wait up to 10 minutes and check the status again. The status may return to Normal and the storage
system will be resyncing.
If status is Storage Server Inoperable
Reboot the storage system and see if it returns to Normal, when it comes back up.
If these statuses recur
This may be an indication that the underlying hardware problem still exists.
Repairing a storage system
Repairing a storage system allows you to replace a failed disk in a storage system that contains
volumes configured for data protection levels other than Network RAID-0, and trigger only one resync
of the data, rather than a complete restriping. Resyncing the data is a shorter operation than a restripe.
Prerequisites
Volume must have Network RAID-10, Network RAID-10+1, Network RAID-10+2, Network RAID-
5, or Network RAID-6.
Storage system must have the blinking red and yellow triangle in the navigation window.
Working with clusters
184