IBM 621410U Hardware Maintenance Manual - Page 118
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S., Adapter in Slot N
UPC - 087944665854
View all IBM 621410U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Error Code/Symptom FRU/Action 015-XXX-015 (Failed USB External Loopback test) 1. Make sure parallel port is not disabled 2. Re-run USB External Loopback test 3. System Board 015-XXX-198 (USB device connected during USB test) 1. Remove USB devices from USB1 and USB2 2. Re-run test 3. System Board 020-XXX-000 1. System Board (Failed PCI Interface test) 030-XXX-000 1. System Board (Failed Internal SCSI interface test) 030-XXX-00N 1. Adapter in Slot N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) 035-XXX-099 1. No adapters were found. 2. If adapter is installed re-check connection. 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. (Check System Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 1. Power Supply (Failed Power Supply test) 089-XXX-001 1. Microprocessor (Failed Microprocessor test) 180-XXX-003 1. System Board (Failed System Board LED test) 110 Hardware Maintenance Manual: IBM IntelliStation E Pro Type 6204 and Type 6214