Dell Force10 S60-44T FTOS Command Line Reference Guide for the S60 System FTOS - Page 751
timers spf
View all Dell Force10 S60-44T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 751 highlights
Related Commands With "not-advertise" parameter configured, this command can be used to filter out some external routes. For example, you want to redistribute static routes to OSPF, but you don't want OSPF to advertise routes with prefix 1.1.0.0. Then you can configure summary-address 1.1.0.0 255.255.0.0 not-advertise to filter out all the routes fall in range 1.1.0.0/16. area range Summarizes routes within an area. timers spf c e s Set the time interval between when the switch receives a topology change and starts a shortest path first (SPF) calculation. Syntax timers spf delay holdtime To return to the default, enter no timers spf. Parameters delay holdtime Enter a number as the delay. Range: 0 to 4294967295. Default: 5 seconds Enter a number as the hold time. Range: 0 to 4294967295. Default: 10 seconds. Defaults Command Modes Command History delay = 5 seconds; holdtime = 10 seconds ROUTER OSPF Version 8.3.3.1 Version 7.8.1.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.1 Introduced on S60 Introduced support of Multi-Process OSPF. Introduced on S-Series Introduced on C-Series Introduced on E-Series Usage Setting the delay and holdtime parameters to a low number enables the switch to switch to an alternate Information path quickly but requires more CPU usage. Open Shortest Path First (OSPFv2 and OSPFv3) | 751