Intel S7000FC4UR Product Guide - Page 116

Installing and Removing the SAS Riser Board (optional), Installing the SAS Riser Board

Page 116 highlights

Installing and Removing the SAS Riser Board (optional) The optional SAS riser board provides support for up to eight internal SAS hard drives. The SAS riser board supports RAID levels 0, 1, 1a, and 10 without any additional components (Integrated RAID mode). With the addition of the Intel® RAID Activation Key and a RAID DIMM, enhanced RAID capability and support for RAID levels 0, 1, 1a, 5, 6, 10, 50, and 60 are enabled. Installing the SAS Riser Board 1. Remove the top cover. For instructions, see "Removing the Top Cover" on page 90. 2. Remove the processor air baffle. For instructions, see "Removing the Processor Air Baffle" on page 92. 3. Lower the SAS riser board into the SAS riser slot, ensuring that the edge of the card is inside of the slot divider. See letter "A" in the following figure. 4. Press down on the card until the metal bracket on the card is flush with the chassis (see letter "B") and locks into place (see letter "C"). A C B Figure 57. Installing SAS Riser Board AF002253 98 Intel® Server System S7000FC4UR Product Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232

98
Intel® Server System S7000FC4UR Product Guide
Installing and Removing the SAS Riser Board (optional)
The optional SAS riser board provides support for up to eight internal SAS hard drives.
The SAS riser board supports RAID levels 0, 1, 1a, and 10 without any additional
components (Integrated RAID mode). With the addition of the Intel
®
RAID Activation
Key and a RAID DIMM, enhanced RAID capability and support for RAID levels 0, 1, 1a,
5, 6, 10, 50, and 60 are enabled.
Installing the SAS Riser Board
1.
Remove the top cover. For instructions, see
“Removing the Top Cover” on page 90
.
2.
Remove the processor air baffle. For instructions, see
“Removing the Processor Air
Baffle” on page 92
.
3.
Lower the SAS riser board into the SAS riser slot, ensuring that the edge of the card
is inside of the slot divider. See letter “A” in the following figure.
4.
Press down on the card until the metal bracket on the card is flush with the chassis
(see letter “B”) and locks into place (see letter “C”).
Figure 57. Installing SAS Riser Board
AF002253
C
A
B