Intel S7000FC4UR Product Guide - Page 117
Removing the SAS Riser Board
UPC - 735858194259
View all Intel S7000FC4UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
5. Connect the SAS riser cables, ensuring that the cables connect to the correct ports on the SAS backplane and SAS riser. The SAS backplane port furthest from the DVD-ROM drive needs to be connected to the lower SAS riser port (letter "A" in the following figure). The SAS backplane port closest to the DVD-ROM drive should be connected to the upper SAS riser port (letter "B" in the figure). Caution: If the cables are connected to the wrong ports, you may observe hard drive functionality issues and / or fault indications. 6. Connect the SES cable to the SAS riser. See letter "C". C B A AF002254 Figure 58. Connecting SAS and SES Cables to SAS Riser Board 7. Install the processor air baffle. For instructions, see "Installing the Processor Air Baffle" on page 94. 8. Install the top cover. For instructions, see "Installing the Top Cover" on page 91. Removing the SAS Riser Board 1. Remove the top cover. For instructions, see "Removing the Top Cover" on page 90. 2. Remove the processor air baffle. For instructions, see "Removing the Processor Air Baffle" on page 92. 3. Remove the two SAS cables from the SAS riser board by pressing on the top of the cable connector and pulling the cable from the SAS port. See the following figure. 4. Remove the SES cable from the SAS riser board. Intel® Server System S7000FC4UR Product Guide 99