Lexmark C750 Service Manual - Page 195
Lexmark C750 Manual
View all Lexmark C750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 195 highlights
5060-00x Factory Defaults The customer can restore either the network settings or the base printer settings to their factory default values. When Restore Base is selected, non-critical base printer NVRAM settings are restored. When Restore Network is selected, all network NVRAM settings are restored to their factory default settings. This option is only available on models with an integrated network adapter. In either case, Restoring Factory Defaults is displayed after the operation is selected. Select Factory Defaults from the CONFIG MENU. =Restore Base =Restore Network Note: Restore Network is only listed on models that have integrated network support. Energy Conserve When Energy Conserve is on, the customer does not have access to disable the Power Saver function. When Energy Conserve is off, Disable appears as an additional menu item in the Power Saver menu. This setting only affects the values that are displayed in the Power Saver Menu. Select Energy Conserve from the CONFIG MENU. =On* =Off ITU Alignment This alignment is required anytime you replace the ITU Assembly. 1. Select ITU Alignment from the CONFIG MENU. A test page is printed. 2. After the test page prints, enter alignment values for each alignment setting. Example: A Alignment 0* On printed sheet: A __ Enter: A Alignment 4 The alignment values range from -10 to + 10 in 0.5 increments (0*). 3. Press Select to continue to the next alignment value. 4. You will be prompted to continue through Test L, pressing Select to save each value. 5. When the tests are done, press Go or Return to exit. Diagnostic aids 3-11