Lexmark C750 Service Manual - Page 209

Lexmark C750 Manual

Page 209 highlights

5060-00x 2000-sheet trays Use this test to determine if the 2000-Sheet Tray sensors are working correctly. 1. Select Sensor Test from the menu for the tray you want to test. The following is displayed: EM=OP NE=OP LE=OP SC=OP The selected tray is displayed on line 1 either Tray 1, 2, 3, or 4. EM NE LE SC =trays empty sensor =trays near empty sensor =trays paper level sensor =input trays side cover sensor 2. Manually actuate the bin sensor by moving the flag in and out of the sensor. OP (Open) appears when the flag is out of the sensor, or CL (Closed) when the flag is in the sensor. OUTPUT BIN TESTS Feed Test Feed to all Bins Diverter Test Sensor Test Feed Test Note: If the "Configure Bins" printer setting is link rather than mailbox, the printer selects its own internal bin linking regardless of which output bin is selected for the feed test. This test verifies that media can be fed to a specific output bin. No information is printed on the media because the printhead is not turned on during this test. To run the Output Bin Feed Test: 1. Select Feed Test from the OUTPUT BIN TESTS menu. 2. Select the output bin you want the paper to exit into. All output bins installed on the printer are shown on 3. 4. the feed test menu. For example, Standard Bin. Select either Single (one sheet of media feeds to the selected output bin) or Continuous (media continues feeding to the selected output bin) until Return or Stop is pressed. Press Return or Stop to exit the test. Feed to All Bins One page is fed to every bin, including the finisher, if available. The test runs continuously until Return or Stop is pressed. Diverter Test This test checks the operation of each mailbox output diverter. Also if more than one 5-Bin mailbox option is installed, the test checks all of the diverters installed on the printer. When the test is selected from the Diagnostics Menu Diverter Test Running is displayed. This is a single test and ends upon completion. Diagnostic aids 3-25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384
  • 385
  • 386
  • 387
  • 388
  • 389
  • 390
  • 391
  • 392
  • 393
  • 394
  • 395
  • 396
  • 397
  • 398
  • 399
  • 400
  • 401
  • 402
  • 403
  • 404
  • 405
  • 406
  • 407
  • 408
  • 409
  • 410
  • 411
  • 412
  • 413
  • 414
  • 415
  • 416
  • 417
  • 418
  • 419
  • 420
  • 421
  • 422
  • 423
  • 424
  • 425
  • 426
  • 427
  • 428
  • 429
  • 430
  • 431
  • 432
  • 433
  • 434
  • 435
  • 436
  • 437
  • 438
  • 439
  • 440
  • 441
  • 442
  • 443
  • 444
  • 445
  • 446
  • 447
  • 448
  • 449
  • 450
  • 451
  • 452
  • 453
  • 454
  • 455
  • 456
  • 457
  • 458
  • 459
  • 460
  • 461
  • 462
  • 463
  • 464
  • 465
  • 466
  • 467
  • 468
  • 469
  • 470
  • 471
  • 472
  • 473
  • 474
  • 475
  • 476
  • 477
  • 478
  • 479
  • 480
  • 481
  • 482
  • 483
  • 484
  • 485
  • 486
  • 487
  • 488
  • 489
  • 490

Diagnostic aids
3-25
5060-00
x
2000-sheet trays
Use this test to determine if the 2000-Sheet Tray sensors are working correctly.
1.
Select
Sensor Test
from the menu for the tray you want to test.
The following is displayed:
The selected tray is displayed on line 1 <
input tray
> either Tray 1, 2, 3, or 4.
2.
Manually actuate the bin sensor by moving the flag in and out of the sensor.
OP
(Open) appears when the
flag is out of the sensor, or
CL
(Closed) when the flag is in the sensor.
OUTPUT BIN TESTS
Feed Test
Feed to all Bins
Diverter Test
Sensor Test
Feed Test
Note:
If the “Configure Bins” printer setting is link rather than mailbox, the printer selects its own internal bin
linking regardless of which output bin is selected for the feed test.
This test verifies that media can be fed to a specific output bin. No information is printed on the media because
the printhead is not turned on during this test.
To run the Output Bin Feed Test:
1.
Select
Feed Test
from the OUTPUT BIN TESTS menu.
2.
Select the output bin you want the paper to exit into. All output bins installed on the printer are shown on
the feed test menu.
For example,
Standard Bin
.
3.
Select either
Single
(one sheet of media feeds to the selected output bin) or
Continuous
(media continues
feeding to the selected output bin) until
Return
or
Stop
is pressed.
4.
Press
Return
or
Stop
to exit the test.
Feed to All Bins
One page is fed to every bin, including the finisher, if available. The test runs continuously until
Return
or
Stop
is pressed.
Diverter Test
This test checks the operation of each mailbox output diverter. Also if more than one 5-Bin mailbox option is
installed, the test checks all of the diverters installed on the printer.
When the test is selected from the Diagnostics Menu
Diverter Test Running
is displayed.
This is a single test and ends upon completion.
<
input tray
>
EM
=OP
NE
=OP
LE
=OP
SC
=OP
EM
=trays empty sensor
NE
=trays near empty sensor
LE
=trays paper level sensor
SC
=input trays side cover sensor