Page 293 highlights
5060-00x Installing the new assembly 1. Remove the J70 connector cable to allow space. Note the route it shares with sensor cable assembly through the frame (see openings D and E below). 2. Place a new cable sensor assembly in the printer next to the sensor connectors (A). 3. Route the J68 connector around the ground clip (B) and cable channel between the upper and lower frame. 4. Route the J68 cable connector through the rectangular opening (D) in the lower frame and out through the opening (E). Note: Guiding the cable through the small opening requires some patience. Use the diagram below and the steps following as a guide. B A C D E G F A -Sensors, part of sensor cable assembly B -Grounding clip C -Cable tie D -Rectangular opening E -Opening F -Cable tie G -J68 connector, sensor cable assembly Repair information 4-75