Lexmark C750 Service Manual - Page 210
Lexmark C750 Manual
View all Lexmark C750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 210 highlights
5060-00x Sensor Test This test verifies if the output bin sensors are working correctly. The following Output options, if installed, are supported by this test. Standard Bin Output Expander 5-Bin Mailbox To run the Output Bin Sensor Test: 1. Select Sensor Test from the menu. 2. Select the bin you want to test. • If Standard Bin is selected the following is displayed. Standard Bin F=OP F =Standard Bin Output Bin Full Sensor • If Output Expander is selected the following is displayed: P=OP F=OP NF=OP P F NF =Output Expander Pass Thru Sensor. =Output Expander Full Sensor =Output Expander Near Full Sensor. • If 5-Bin Mailbox is selected the following is displayed: P1=OP P2=OP L=NL P1 P2 L =5-Bin Mailbox first Pass Thru Sensor. =5-Bin Mailbox second Pass Thru Sensor. =5-Bin Mailbox output level sensor where: EM indicates the bin is empty. NL indicates the bin contains media but the bin is not near full nor full. NF indicates the bin is near full. FL indicates the bin is full. 3. Once the selection is displayed you can manually actuate the sensor you want to test. When the sensor is closed (CL) displays, and when the sensor is open (OP) displays. 4. To exit the test press Return or Stop. 3-26 Service Manual