3Com 3C63311 Reference Guide - Page 162
At PathBuilder S330 A S330 A, Add a virtual circuit VC 2 between S330 C and S330 A.
View all 3Com 3C63311 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 162 highlights
150 CHAPTER 4: CONFIGURING PATHBUILDER S330/S310 MODULES, PORTS, AND APPLICATIONS For the purposes of this example, assume you want to make the following connections: n Connect subchannels 1-4 on PBX-1 to subchannels 1-4 on PBX-2 n Connect subchannels 5-8 on PBX-1 to subchannels 1-4 on PBX-3. You need to build the following VCM VCC and subchannel circuits: At PathBuilder S330 A (S330 A): n Add a virtual circuit (VC 1) between S330 A and S330 B. n Add a virtual circuit (VC 2) between S330 A and S330 C. n Add four subchannel circuits to VC 1, setting the VCM circuit parameters as follows: n DS0: 1-4 n DLCI:16 n SCID: 11-14 n Add four subchannel circuits to VC 2, setting the VCM circuit parameters as follows: n DS0: 5-8 n DLCI:17 n SCID: 11-14 At PathBuilder S330 B (S330 B): n Add a virtual circuit (VC 1) between S330 B and S330 A. n Add four subchannel circuits to VC 1, setting the VCM circuit parameters as follows: n DS0: 1-4 n DLCI:16 n SCID: 11-14 At PathBuilder S330 C (S330 C): n Add a virtual circuit (VC 2) between S330 C and S330 A. n Add four subchannel circuits to VC 2, setting the VCM circuit parameters as follows: n DS0: 1-4 n DLCI:17 n SCID: 11-14