Dell PowerConnect B-DCX4S Hardware Reference Guide - Page 120

Obtaining chassis and component status, Interpreting POST and boot results, POST

Page 120 highlights

C Obtaining chassis and component status Obtaining chassis and component status The CLI commands in Table 25 provide status and environmental information about the chassis and its components. These commands provide information only, and they do not interrupt traffic flow. For more information about these commands, refer to the Fabric OS Command Reference. TABLE 25 Command Environmental status and maintenance commands Information displayed sensorShow tempShow psShow fanShow chassisShow slotShow errShow errDump Temperature readings for the port blades Temperature readings for the CP blades Status and RPM of all operational fans Status of all operational power supplies Temperature readings for the port blades Temperature readings for the CP blades Status of all operational power supplies Status and RPM of all operational fans Serial number, time awake, and additional information about each component Slot occupancy System error log. Refer to the Fabric OS Message Reference for more information on the messages in this log. Interpreting POST and boot results The PowerConnect B-DCX-4S performs Power On Self Test (POST) by default each time the chassis is powered on, rebooted, or reset. The PowerConnect B-DCX-4S can be rebooted using the reboot (to reboot each CP individually) or fastBoot commands. The fastBoot command reboots the switches without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade. POST To verify that POST has completed without error: • Verify that all LEDs return to a normal state after POST completes (Chapter 4, "Monitor System Components"). If one or more LEDs do not return to a normal state, and this is not due to the PowerConnect B-DCX-4S being set to beacon, refer to the relevant LED table to identify and correct the problem. For port blades and CP and core switch blades, the slotShow command can be used to check the status of the slots. For information about turning beaconing on/off, refer to the Fabric OS Administrator's Guide. • Verify that the switch prompt displays when POST completes. If it does not display, POST was not successfully completed. Contact the PowerConnect B-DCX-4S supplier for support. • Review the system error log using the errShow or errDump commands. 106 PowerConnect B-DCX-4S Backbone Hardware Reference Manual 53-1001808-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

106
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
53-1001808-01
Obtaining chassis and component status
C
Obtaining chassis and component status
The CLI commands in
Table 25
provide status and environmental information about the chassis
and its components. These commands provide information only, and they do not interrupt traffic
flow. For more information about these commands, refer to the
Fabric OS Command Reference.
Interpreting POST and boot results
The PowerConnect B-DCX-4S performs Power On Self Test (POST) by default each time the chassis
is powered on, rebooted, or reset. The PowerConnect B-DCX-4S can be rebooted using the
reboot
(to reboot each CP individually) or
fastBoot
commands. The
fastBoot
command reboots the
switches without running POST. If the active CP blade is rebooted, it fails over to the standby CP
blade.
POST
To verify that POST has completed without error:
Verify that all LEDs return to a normal state after POST completes (
Chapter 4, “Monitor System
Components”
).
If one or more LEDs do not return to a normal state, and this is not due to the PowerConnect
B-DCX-4S being set to beacon, refer to the relevant LED table to identify and correct the
problem. For port blades and CP and core switch blades, the
slotShow
command can be used
to check the status of the slots. For information about turning beaconing on/off, refer to the
Fabric OS Administrator’s Guide
.
Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the PowerConnect
B-DCX-4S supplier for support.
Review the system error log using the
errShow
or
errDump
commands.
TABLE 25
Environmental status and maintenance commands
Command
Information displayed
sensorShow
Temperature readings for the port blades
Temperature readings for the CP blades
Status and RPM of all operational fans
Status of all operational power supplies
tempShow
Temperature readings for the port blades
Temperature readings for the CP blades
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about each component
slotShow
Slot occupancy
errShow
errDump
System error log. Refer to the
Fabric OS Message Reference
for more information on the
messages in this log.