Dell PowerConnect B-DCX4S Hardware Reference Guide - Page 26
Preparing for PowerConnect B-DCX-4S installation
View all Dell PowerConnect B-DCX4S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
2 Preparing for PowerConnect B-DCX-4S installation TABLE 3 Installation tasks, time, and items required (Continued) Installation task Time estimate Items required Installing the rack mount kit or port side exhaust kit. Mounting and securing PowerConnect B-DCX-4S in rack. 30 minutes 15 minutes Installing power cables and powering on the PowerConnect B-DCX-4S. Establishing serial connection, logging on to PowerConnect B-DCX-4S, and configuring IP addresses. 10 minutes 20 minutes Installing an Ethernet cable, opening a Telnet session, and configuring the PowerConnect B-DCX-4S domain ID, date and time, and additional system parameters. Verify and back up configuration. Installing SFPs. Attaching and managing fiber optic cables. 20 minutes 15 minutes Refer to the one of the following if you are mounting the PowerConnect B-DCX-4S in a rack: PowerConnect B-Port Side Exhaust Kit Installation Procedure PowerConnect B-DCX-4S Mid-Mount Rack Kit Installation Procedure or PowerConnect B-DCX-4S Rack Kit Installation Procedure . Power cables. Serial cable (provided in the accessory kit). Workstation computer with a serial port or terminal server port and a terminal emulator application (such as HyperTerminal). Ethernet IP addresses for the switch. Ethernet cable for Telnet access. Refer to the Fabric OS Administrator's Guide. SFP optical transceivers. Fiber optic cables and cable ties. Preparing for PowerConnect B-DCX-4S installation NOTE Read the safety notices before installation ("Safety notices"). The following steps are required to ensure correct installation and operation. 1. Provide a space that is 9 rack units (9U) high, 61.19 cm (24.09 in.) deep, and 43.74 cm (17.22 in.) wide. 1U is equal to 4.45 cm (1.75 in.). If you do not use the provided port side exhaust kit, the space needs to be only 8 rack units (8U) high. The PowerConnect B-DCX-4S can be installed facing either direction in a cabinet, if serviceability and cooling requirements are met. 2. Ensure that dedicated electrical branch circuits with the following characteristics are available: • 200 - 240 VAC, 50-60 Hz (two branch circuits) • Two cables for the 200 - 240 VAC service • Power supply standards ("Power specifications") are met • Protected by a circuit breaker in accordance with local electrical codes • Supply circuit, line fusing, and wire size adequate to the electrical rating on the chassis nameplate • Location close to the chassis and easily accessible 12 PowerConnect B-DCX4S Backbone Hardware Reference Manual 53-1001808-01