Dell PowerConnect B-DCX4S Hardware Reference Guide - Page 96
Verifying correct configuration of the fabric, Number of devices
View all Dell PowerConnect B-DCX4S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
5 RRP: PowerConnect B-DCX-4S chassis d. Organize the cables as required. Verifying correct configuration of the fabric Copying the command outputs from this section into a file is recommended. 1. Create an "after" SAN profile by entering the following commands and copying the output to a text file named "SANafter.txt": • nsShow • nsAllShow • switchShow • fabricShow • lscfg --show (if using the virtual fabric feature) switch:admin> nsshow Type Pid COS PortName NodeName TTL(sec) N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na Fabric Port Name: 20:0f:00:60:69:90:03:f0 switch:admin> nsallshow { 020f00 021fda 021fdc 021fe0 021fe1 5 Nx_Ports in the Fabric} switch:admin> switchshow switchName: rsl8-st03-dcx-01 switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name switch:admin>lscfg --show Created switches: 128(ds) 1 2(bs) Port 0 1 2 3 4 5 6 7 8 9 FID 1 | 1 | 1 | 1 | 1 | 128 | 128 | 128 | 128 | 128 | switch:admin> 2. Determine any differences between the information in the "SANafter.txt" file and the information in the "SANbefor.txt" file created earlier. In particular, look for differences in the following: • Device types • Number of devices • ISL and port states • Number of switches in the fabric 3. Resolve any issues or unintentional changes to the PowerConnect B-DCX-4S or fabric. • If there are any mechanical problems, try reseating the associated component. 82 PowerConnect B-DCX-4S Backbone Hardware Reference Manual 53-1001808-01