Dell PowerEdge 1950 Hardware Owner's Manual (PDF) - Page 20
PS Redundancy, I/O Channel Chk, PCI PERR Slot, Unknown Err, E171F, PCIE Fatal Err - e171f pcie fatal error
View all Dell PowerEdge 1950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Table 1-7. LCD Status Messages (continued) Code E1624 E1710 E1711 E1712 E1714 E171F Text Causes Corrective Actions PS Redundancy The power supply subsystem is no See "Troubleshooting Power longer redundant. If the last supply Supplies" on page 100. fails, the system will go down. I/O Channel Chk The system BIOS has reported an See "Getting Help" on page 125. I/O channel check. PCI PERR B## D## F## PCI PERR Slot # The system BIOS has reported a PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##. The system BIOS has reported a PCI parity error on a component that resides in the specified PCI slot. Remove and reseat the PCI expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 107. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 125. PCI SERR B## D## F## PCI SERR Slot # The system BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##. The system BIOS has reported a PCI system error on a component that resides in the specified slot. Remove and reseat the PCI expansion cards. If the problem persists, see "Getting Help" on page 125. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 125. Unknown Err The system BIOS has determined that there has been an error in the system, but is unable to determine its origin. See "Getting Help" on page 125. PCIE Fatal Err B## D## F## PCIE Fatal Err Slot # The system BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. The system BIOS has reported a PCIe fatal error on a component that resides in the specified slot. Remove and reseat the PCI expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 107. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 125. E1810 HDD ## Fault The SAS subsystem has See "Troubleshooting a Hard determined that hard drive ## has Drive" on page 104. experienced a fault. 20 About Your System