Dell PowerEdge 1950 Hardware Owner's Manual (PDF) - Page 26
Ensure that the Remote Access Controller, See Troubleshooting System Memory - memory upgrade
View all Dell PowerEdge 1950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Table 1-8. System Messages (continued) Message Causes Corrective Actions DIMMs must be populated in sequential order beginning with slot 1. The following DIMM is electrically isolated: DIMM x. The specified DIMM is inaccessible to the system due to its location. DIMMs must be populated in sequential order, beginning with slot 1. Populate 2, 4, 8, or 12 DIMMs sequentially beginning with slot 1. See "System Memory" on page 63. DIMMs should be installed in pairs. Pairs must be matched in size, speed, and technology. Mismatched or unmatched DIMMs Ensure that all pairs of memory modules installed; faulty or improperly seated are of the same type and size and that they memory module(s). The system will are properly installed. See "System operate in a degraded mode with Memory" on page 63. If the problem reduced ECC protection. Only memory persists, see "Troubleshooting System installed in channel 0 will be Memory" on page 102. accessible. Dual-rank DIMM paired with Single-rank DIMM - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y Mismatched DIMMs installed; faulty Ensure that all pairs of memory modules memory module(s). The system has are of the same type and size and that they detected a dual-rank DIMM paired with are properly installed. See "System a single-rank DIMM. The second rank Memory" on page 63. If the problem of the dual-rank DIMM will be persists, see "Troubleshooting System disabled. Memory" on page 102. Error: Incorrect memory configuration. DIMMs must be installed in pairs of matched memory size, speed, and technology. Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "System Memory" on page 63. If the problem persists, see "Troubleshooting System Memory" on page 102. Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible. Faulty or improperly seated memory See "Troubleshooting System Memory" module(s). on page 102. !!*** Error: Remote Access Controller initialization failure*** RAC virtual USB devices may not be available... Remote Access Controller initialization Ensure that the Remote Access Controller failure. is properly installed. See "RAC Card" on page 71. FBD training error: The following branch has been disabled: Branch x The specified branch (channel pair) Ensure that only Dell-qualified memory is contains DIMMs that are incompatible used. Dell recommends purchasing with each other. memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility. Gate A20 failure Faulty keyboard controller; faulty system board. See "Getting Help" on page 125. 26 About Your System