Dell PowerEdge 1950 Hardware Owner's Manual (PDF) - Page 27

a Hard Drive on See Using - not seeing hard drive

Page 27 highlights

Table 1-8. System Messages (continued) Message Causes Corrective Actions General failure The operating system is unable to carry This message is usually followed by out the command. specific information. Note the information, and take the appropriate action to resolve the problem. Invalid NVRAM configuration, Resource Re-allocated System detected and corrected a resource conflict. No action is required. Keyboard Controller failure Faulty keyboard controller; faulty system board See "Getting Help" on page 125. Manufacturing mode detected System is in manufacturing mode. Reboot to take the system out of manufacturing mode. MEMBIST failure - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y Faulty memory module(s). See "Troubleshooting System Memory" on page 102. Memory address line failure at address, read value expecting value Faulty or improperly installed memory See "Troubleshooting System Memory" modules. on page 102. Memory double word logic failure at address, read value expecting value Memory odd/even logic failure at address, read value expecting value Memory write/read failure at address, read value expecting value Memory tests terminated by POST memory test terminated by keystroke. pressing the spacebar. Information only. No boot device available Faulty or missing optical drive subsystem, hard drive, or hard-drive subsystem, or no boot disk in drive A. Use a CD or hard drive. If the problem persists, see "Troubleshooting an Optical Drive" on page 103 and "Troubleshooting a Hard Drive" on page 104. See "Using the System Setup Program" on page 31 for information on setting the order of boot devices. About Your System 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

About Your System
27
General failure
The operating system is unable to carry
out the command.
This message is usually followed by
specific information. Note the
information, and take the appropriate
action to resolve the problem.
Invalid NVRAM
configuration, Resource
Re-allocated
System detected and corrected a
resource conflict.
No action is required.
Keyboard Controller
failure
Faulty keyboard controller; faulty
system board
See "Getting Help" on page 125.
Manufacturing mode
detected
System is in manufacturing mode.
Reboot to take the system out of
manufacturing mode.
MEMBIST failure - The
following DIMM/rank has
been disabled by BIOS:
DIMM x Rank y
Faulty memory module(s).
See "Troubleshooting System Memory"
on page 102.
Memory address line
failure at
address
, read
value
expecting
value
Faulty or improperly installed memory
modules.
See "Troubleshooting System Memory"
on page 102.
Memory double word logic
failure at
address
, read
value
expecting
value
Memory odd/even logic
failure at
address,
read
value
expecting
value
Memory write/read failure
at
address
, read
value
expecting
value
Memory tests terminated by
keystroke.
POST memory test terminated by
pressing the spacebar.
Information only.
No boot device available
Faulty or missing optical drive
subsystem, hard drive, or hard-drive
subsystem, or no boot disk in drive A.
Use a CD or hard drive. If the problem
persists, see "Troubleshooting an Optical
Drive" on page 103 and "Troubleshooting
a Hard Drive" on page 104. See "Using
the System Setup Program" on page 31
for information on setting the order of
boot devices.
Table 1-8.
System Messages
(continued)
Message
Causes
Corrective Actions