Dell PowerEdge 1950 Hardware Owner's Manual (PDF) - Page 25
System Messages - bios update
View all Dell PowerEdge 1950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
System Messages System messages appear on the screen to notify you of a possible problem with the system. Table 1-8 lists the system messages that can occur and the probable cause and corrective action for each message. NOTE: If you receive a system message that is not listed in Table 1-8, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action. CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product. Table 1-8. System Messages Message Causes Corrective Actions Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Installed memory modules are not the same type and size; faulty memory module(s). Ensure that all memory modules are of the same type and size and that they are properly installed. If the problem persists, see "Troubleshooting System Memory" on page 102. Attempting to update Remote Configuration. Please wait... Remote Configuration request has been Wait until the process is complete. detected and is being processed. BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If the problem persists, see "Getting Help" on page 125. Caution! NVRAM_CLR jumper NVRAM_CLR jumper is installed. is installed on system CMOS has been cleared. board. Remove NVRAM_CLR jumper. See Figure 6-1 for jumper location. CPUs with different cache sizes detected! Microprocessors with different cache sizes are installed. Ensure that all microprocessors have the same cache size and that they are properly installed. See "Processors" on page 67. Decreasing available memory Faulty or improperly installed memory See "Troubleshooting System Memory" modules. on page 102. DIMM pairs must be matched in size, speed, and technology. The following DIMM pair is mismatched: DIMM x and DIMM y. Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "System Memory" on page 63. If the problem persists, see "Troubleshooting System Memory" on page 102. About Your System 25