Dell PowerEdge 1950 Hardware Owner's Manual (PDF) - Page 23
SBE Log Disable, Mem Spare Crd, Mem Mirror Crd, Fatal NB Mem CRC, Fatal SB Mem CRC, Intrusion, >3 - e2111 sbe log disable
View all Dell PowerEdge 1950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Table 1-7. LCD Status Messages (continued) Code E2111 E2112 E2113 E2118 E2119 I1910 I1911 Text Causes Corrective Actions SBE Log Disable Crd # DIMM ## The system BIOS has disabled See "Troubleshooting System memory single-bit error (SBE) Memory" on page 102. logging, and will not resume logging further SBEs until the system is rebooted. "##" represents the DIMM implicated by the BIOS. If no memory riser card is present, the "Crd #" string is left out of the message. Mem Spare Crd # DIMM ## The system BIOS has spared the See "Troubleshooting System memory because it has determined Memory" on page 102. that the memory had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. If no memory card is present, the "Crd #" string is left out of the message. Mem Mirror Crd # DIMM ## & ## The system BIOS has disabled See "Troubleshooting System memory mirroring because it has Memory" on page 102. determined that one half of the mirror has had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS. If no memory card is present, the "Crd #" string is left out of the message. Fatal NB Mem CRC One of the connections in the FBD See "Troubleshooting System memory subsystem link on the Memory" on page 102. Northbound side has failed. Fatal SB Mem CRC One of the connections in the FBD See "Troubleshooting System memory subsystem link on the Memory" on page 102. Southbound side has failed. Intrusion System cover has been removed. Information only. >3 ERRs Chk Log LCD overflow message. Check the SEL for details on the A maximum of three error events. messages can display sequentially on the LCD. The fourth message displays as the standard overflow message. About Your System 23