Page 172 highlights
Lithium Ion Handle Battery Pack Dimensions Height Length Width Weight Energy Voltage Amp-hour Capacity Watt-hour Capacity Environmental Requirements Operating temperatures Nonoperating temperature U.S. 0.89 in 11.00 in 1.53 in 0.88 lb 14.4 V dc 2.6 Ah 37.4 Wh 50°F to 104°F -120F to 1400F Metric 15.2 mm 279.0 mm 38.8 cm 399 g 10°C to 40°C -300C to 600C Nickel Metal Hydride Handle Battery Pack Dimensions Height Length Width Weight Energy Voltage Amp-hour Capacity Watt-hour Capacity Environmental Requirements Operating temperatures Nonoperating temperature U.S. 0.89 in 11.00 in 1.53 in 1.05 lb 12.0 V dc 2.1 Ah 25.0 Wh 50°F to 104°F -40F to 860F Metric 15.2 mm 279.0 mm 38.8 mm 457 g 10°C to 40°C -200C to 300C G-6 Specifications
G-6
Specifications
Lithium Ion Handle Battery Pack
U.S.
Metric
Dimensions
Height
0.89 in
15.2
mm
Length
11.00 in
279.0
mm
Width
1.53 in
38.8
cm
Weight
0.88
lb
399 g
Energy
Voltage
14.4 V dc
Amp-hour Capacity
2.6 Ah
Watt-hour Capacity
37.4 Wh
Environmental Requirements
Operating temperatures
50°F to 104°F
10
°
C to 40
°
C
Nonoperating temperature
-12
0
F to 140
0
F
-30
0
C to 60
0
C
Nickel Metal Hydride Handle Battery Pack
U.S.
Metric
Dimensions
Height
0.89 in
15.2
mm
Length
11.00 in
279.0
mm
Width
1.53 in
38.8
mm
Weight
1.05
lb
457 g
Energy
Voltage
12.0 V dc
Amp-hour Capacity
2.1 Ah
Watt-hour Capacity
25.0 Wh
Environmental Requirements
Operating temperatures
50°F to 104°F
10
°
C to 40
°
C
Nonoperating temperature
-4
0
F to 86
0
F
-20
0
C to 30
0
C