enclosure set temperature, Before setting the threshold temperature, you might want to use
View all HP Workstation xw6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 289 highlights
enclosure Commands enclosure set temperature To set the temperature threshold on a specific SAF-TE enclosure management device, use the enclosure set temperature command. Typically, an enclosure management device contains individual temperature sensors. With this command, you can set a temperature threshold so that the enclosure management device alerts you if one or more of the temperature sensors exceeds the threshold. Syntax enclosure set temperature {enclosure} {degree} Parameters {enclosure} Specifies the ID associated with the enclosure management device on which you want to set a temperature threshold. For this version, the controller supports a maximum of eight enclosure management devices on each bus. {degree} Specifies the temperature (in degrees Fahrenheit) at which you want to set the threshold for this enclosure management device. You can specify from 0 to 255 degrees Fahrenheit. The default is 120 degrees Fahrenheit. Examples Before setting the threshold temperature, you might want to use the enclosure show temperature command to determine the current temperature(s). As the following example shows, the current temperature is 70 degrees Fahrenheit and the threshold setting is 120 degrees Fahrenheit: Enclosure Sensor Temperature Threshold Status 0 0 70 F 120 NORMAL The following example sets the threshold temperature associated with enclosure management device 0 to 100 degrees Fahrenheit: 11-25