Icom IC-7700 Instruction Manual - Page 198

Color setting

Page 198 highlights

14 CONTROL COMMAND D Offset frequency setting The following data sequence is used when sending or reading the offset frequency setting. q w e r* X0XX0X XX D Color setting The following data sequence is used when sending or reading the color setting. qwerty 0XXX0XXX0XXX 1 kHz digit: 0-9 100 Hz digit: 0 (fixed) 100 kHz digit: 0-9 10 kHz digit: 0-9 10 MHz digit: 0-9† 1 MHz digit: 0-4 Direction: 00=+ direction 01=- direction 1000 100 10 1 1000 100 10 1 1000 100 10 1 R (Red) G (Green) B (Blue) Using 0000-0255 for each color element. *No need to enter for transverter offset frequency setting. †Transverter offset only; Fix to '0' for split offset setting. D Repeater tone/tone squelch frequency setting The following data sequence is used when sending or reading the tone frequency setting. q* w e 0 0XXXX D Bandscope edge frequency setting The following data sequence is used when sending or reading the bandscope edge frequency setting. qwerty X XXXXXXXXXXX Lower edge Higher edge Fixed digit: 0* Fixed digit: 0* 100Hz digit: 0-2 10 Hz digit: 0-9 1 Hz digit: 0-9 0.1 Hz digit: 0-9 1 kHz: 0-9 100 Hz: 0 (fixed) 100 kHz: 0-9 10 kHz: 0-9 10 MHz: 0-6 1 MHz: 0-9 1 kHz: 0-9 100 Hz: 0 (fixed) 100 kHz: 0-9 10 kHz: 0-9 10 MHz: 0-6 1 MHz: 0-9 *Not necessary when setting a frequency. D SSB transmission passband width setting The following data sequence is used when sending or reading the SSB transmission passband width setting. XX Lower edge: 0=100 Hz 1=200 Hz 2=300 Hz 3=500 Hz Higher edge: 0=2500 Hz 1=2700 Hz 2=2800 Hz 3=2900 Hz D Data mode with filter width setting The following data sequence is used when sending or reading the data mode with filter width setting. qw X XXX 00=Data mode OFF 01=FIL1 02=FIL2 03=FIL3 00=Data mode OFF 01=Data mode 1 (D1) 02=Data mode 2 (D2) 03=Data mode 3 (D3) D Antenna memory setting The following codes are used when sending or reading the antenna memory setting. 0=ANT1, 1=ANT2, 2=ANT3, 3=ANT4, 4*=TX: ANT1, RX: ANT4, 5*=TX: ANT2, RX: ANT4, 6*=TX: ANT3, RX: ANT4 *RX should be selected for ANT4 14-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

14-10
14
CONTROL COMMAND
D
Offset frequency setting
The following data sequence is used when sending or
reading the offset frequency setting.
D
Repeater tone/tone squelch frequency
setting
The following data sequence is used when sending or
reading the tone frequency setting.
D
SSB transmission passband width
setting
The following data sequence is used when sending or
reading the SSB transmission passband width setting.
D
Color setting
The following data sequence is used when sending or
reading the color setting.
D
Bandscope edge frequency setting
The following data sequence is used when sending or
reading the bandscope edge frequency setting.
D
Data mode with filter width setting
The following data sequence is used when sending or
reading the data mode with filter width setting.
D
Antenna memory setting
The following codes are used when sending or read-
ing the antenna memory setting.
0=ANT1, 1=ANT2, 2=ANT3, 3=ANT4,
4*=TX: ANT1, RX: ANT4, 5*=TX: ANT2, RX: ANT4,
6*=TX: ANT3, RX: ANT4
*RX should be selected for ANT4
q
X
X
X
X
w
00=Data mode OFF
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF
01=Data mode 1 (D1)
02=Data mode 2 (D2)
03=Data mode 3 (D3)
1 kHz: 0–9
100 Hz: 0 (fixed)
100 kHz: 0–9
10 kHz: 0–9
10 MHz: 0–6
1 MHz: 0–9
1 kHz: 0–9
100 Hz: 0 (fixed)
100 kHz: 0–9
10 kHz: 0–9
10 MHz: 0–6
1 MHz: 0–9
q
X
X
X
X
X
X
X
X
X
X
X
X
w
e
r
t
y
Lower edge
Higher edge
1000
100
10
1
q
0
X
X
X
0
X
X
X
0
X
X
X
w
e
r
t
y
1000
100
10
1
1000
100
10
1
R (Red)
G (Green)
B (Blue)
Using 0000–0255 for each color element.
X
X
Higher edge: 0=2500 Hz
1=2700 Hz
2=2800 Hz
3=2900 Hz
Lower edge:
0=100 Hz
1=200 Hz
2=300 Hz
3=500 Hz
100Hz digit: 0–2
10 Hz digit: 0–9
1 Hz digit: 0–9
0.1 Hz digit: 0–9
Fixed digit: 0*
Fixed digit: 0*
q
*
0
0
X
X
X
w
e
X
*Not necessary when setting a frequency.
1 kHz digit: 0–9
100 Hz digit: 0 (fixed)
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–4
Direction:
00=+ direction
01=– direction
q
0
X
X
X
X
XX
w
e
0
r
*
*No need to enter for transverter offset frequency setting.
Transverter offset only; Fix to ‘0’ for split offset setting.