Icom IC-7700 Instruction Manual - Page 86
Tone squelch operation
View all Icom IC-7700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
4 RECEIVE AND TRANSMIT ■ Tone squelch operation TONE DEF F-4 ∫ √ AM/FM Main dial F-1 F-2 The tone squelch opens only when receiving a signal containing a matching subaudible tone. You can silently wait for calls from group members using the same tone. q Set the desired frequency band and select FM mode. w Push [TONE] (MF6) to turn the tone squelch function ON. • " TSQL " appears e Push and hold [TONE] (MF6) for 1 sec. to tone frequency set mode. r Push [Y] F-1 or [Z] F-2 to select T-SQL TONE item. t Rotate the main dial to select the desired tone squelch frequency. • Push and hold [DEF] F-4 for 1 sec. to select the default setting. y Push EXIT/SET to return to the previous indication. u When the received signal includes a matching tone, squelch opens and the signal can be heard. • When the received signal's tone does not match, tone squelch does not open. However, the S-indicator shows signal strength. • To open the squelch manually, push [XFC]. i Operate the transceiver in the normal way. o To cancel the tone squelch, push [TONE] (MF6) to clear "TSQL." • Available tone frequencies (unit: Hz) 67.0 085.4 107.2 136.5 165.5 186.2 210.7 254.1 69.3 088.5 110.9 141.3 167.9 189.9 218.1 71.9 091.5 114.8 146.2 171.3 192.8 225.7 74.4 094.8 118.8 151.4 173.8 196.6 229.1 77.0 097.4 123.0 156.7 177.3 199.5 233.6 79.7 100.0 127.3 159.8 179.9 203.5 241.8 82.5 103.5 131.8 162.2 183.5 206.5 250.3 4-34