Konica Minolta AccurioPress C14000 Plockmatic PowerSquare R2L User Manual - Page 114
Change the Fuses - PowerSquare 224, Introduction, Fuse Description, Procedure, Result
View all Konica Minolta AccurioPress C14000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
5 - Troubleshooting - Change the Fuses - PowerSquare 224 Change the Fuses - PowerSquare 224 Introduction The PowerSquare 224 has two fuses at the mains power input. See Figure 4 on page 6. If either fuse is broken, the PowerSquare 224 will not operate. Warning: Electrical Shock Hazard Turn OFF the machine and remove the mains power supply cable before you change the fuses. This machine uses two fuses in parallel. Warning: Electrical Fire Hazard Always replace a fuse with one that is of the same type and that has the same rating. An incorrect fuse can cause a fire. Fuse Description • 7A, HRC Quick acting, F • Part Number 4-730-018 Procedure 1. Turn OFF the PowerSquare 224. 2. Disconnect the PowerSquare 224 from the mains power supply. 3. Turn one fuse-holder to the left and remove the fuse-holder from the PowerSquare 224 4. Check the fuse. 5. If the fuse is broken then replace with a fuse of the correct specification. 6. Repeat the procedure for the other fuse. Result If the fuse breaks again, then call your Plockmatic service engineer. 108 Plockmatic PowerSquare™224 User Manual