Konica Minolta AccurioPress C14000 Plockmatic PowerSquare R2L User Manual - Page 138
Install the Stitch-wire into the Stitch Head, Close the PowerSquare 224, See Lower the Clincher Frame
View all Konica Minolta AccurioPress C14000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
6 - Maintenance - Install New Stitch-wire Install the Stitch-wire into the Stitch Head Step Action Information 1 Pull the stitch-wire from the end of the stitch-wire guide. 2 Make sure the stitch-wire runs behind the gas-strut. 3 Feed the end of the stitch-wire between the felt wire-cleaning pads. Felt Wire-Cleaning Pads 4 Push the stitch-wire into the stitch- wire guide block. Push stitch-wire in direction of arrow 5 Push the stitch-wire as far as pos- sible. Make sure the stitch-wire runs between the wire feed rollers and into the middle wire tube. Close the PowerSquare 224 Step Action Information 1 Close the stitch wire cabinet. 2 Lower the PowerSquare 224 main deck. 3 Lower the clincher frame. See "Lower the Clincher Frame" on page 43. 4 Close the folder cover. 132 Plockmatic PowerSquare™224 User Manual