Konica Minolta AccurioPress C14000 Plockmatic PowerSquare R2L User Manual - Page 47
Open and Close the Folder Cover, Caution, Important
View all Konica Minolta AccurioPress C14000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
4 - Jobs - Open and Close the Folder Cover Open and Close the Folder Cover When to do If a machine error occurs, or for maintenance. • To access the stitch area • To access the folder area Note: The PSQ224 will stop if you open the folder cover. Caution: Use extreme caution if the error message FOLD BLADE NOT PARKED is shown on the screen. If you feel any resistance when you open the folder cover stop immediately, then call you service engineer. If the folder cover is forced open it can cause damage to the PSQ224. FIGURE 16. Unlock and Lock the Folder Cover Before you start Important: Check the touch screen for the error message FOLD BLADE NOT PARKED. If the error message is displayed. If the error message is not displayed. If the folder cover will open without resistance, remove any paper, then close the folder cover. Touch START , then follow the instructions on the screen. Wait for the message to clear. Then continue with the procedure below. If you feel any resistance when you open the folder cover stop immediately, then call you service engineer. Continue with the procedure below. Plockmatic PowerSquare™224 User Manual 41