Panasonic WJ-HD716/1000 Operating Instructions - Page 19

RAID recovery failed RAID 5/RAID, Indication, Description

Page 19 highlights

Indication Error Description Indication 1DOWN: A single hard disk drive in RAID (RAID 5/RAID 6) is faulty (which can be recovered by replacing the hard disk drive) 2DOWN: 2 hard disk drives in RAID (RAID 5/ RAID 6) are faulty (which can be recovered by replacing the hard disk drives when operating in the RAID 6 mode) 3DOWN: 3 hard disk drives in the RAID 6 mode are faulty (which cannot be recovered by replacing the hard disk drives) FAN: Cooling fan error occurred SWAR-ERR: A hard disk drive was removed without pressing the [USE] button during the recording is running R-FAIL: RAID recovery failed (RAID 5/RAID 6) F-FAIL: Failed to format the hard disk drive "*" indicates the camera channel (1 - 16). "C" indicates the partition (See the descrip- tions.) "**" indicates a number (%) of the remaining disk Note: • Refer to the Installation Guide for further information about each error. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

19
Indication
Description
Indication
Error
1DOWN:
A single hard disk drive in RAID
(RAID 5/RAID 6) is faulty (which can
be recovered by replacing the hard
disk drive)
2DOWN:
2 hard disk drives in RAID (RAID 5/
RAID 6) are faulty (which can be
recovered by replacing the hard
disk drives when operating in the
RAID 6 mode)
3DOWN:
3 hard disk drives in the RAID 6
mode are faulty (which cannot be
recovered by replacing the hard
disk drives)
FAN:
Cooling fan error occurred
SWAR-ERR:
A hard disk drive was removed
without pressing the [USE] button
during the recording is running
R-FAIL:
RAID recovery failed (RAID 5/RAID
6)
F-FAIL:
Failed to format the hard disk drive
"*" indicates the camera channel
(1 - 16).
"
C
" indicates the partition (See the descrip-
tions.)
"**" indicates a number (%) of the remaining disk
Note:
• Refer to the Installation Guide for further information about each error.