IBM 887022X Maintenance Manual - Page 110
disconnect
UPC - 000435151957
View all IBM 887022X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
7. Remove the EMC shield from the server. SMP Expansion Cables EMC Shield NOTE: FOR PROPER FRONT OF BOX AIRFLOW, NOTE: FOR PROPER AIRFLOW, FRONT OF BOX REPLACE FAN WITHIN 2 MINUTES REPLACE FAN WITHIN 2 MINUTES Figure 48. Removing the EMC shield SMP baffle a. If necessary, disconnect the SMP Expansion cables that are connected to the SMP Expansion Modules. b. Loosen the blue thumbscrews holding the EMC shield to the server. c. Remove the EMC shield from the rear of the server. NOTE: FOR PROPER FRONT OF BOX AIRFLOW, NOTE: FOR PROPER AIRFLOW, FRONT OF BOX REPLACE FAN WITHIN 2 MINUTES REPLACE FAN WITHIN 2 MINUTES Figure 49. Rotate the locking levers to remove the SMP Expansion Module 8. Grasp each of the locking levers ( 1 ) on the top of the SMP Expansion Module, and lift them up slightly. 9. Working from the right side of the server, rotate the two locking levers ( 1 ) toward you until they are fully extended, as shown. 10. Slide ( 2 ) the SMP Expansion Module away from the center plane slightly, toward the right side of the server. Attention: When removing the SMP Expansion Module from the server, lift it out carefully, taking care not to damage the components on the center plane. 100 xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide