IBM 887022X Maintenance Manual - Page 232
-0xx
UPC - 000435151957
View all IBM 887022X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 232 highlights
Note: See Chapter 8, "Parts listing, Type 8870," on page 249 to determine which components are replaceable by the customer, and which components should be replaced by an IBM field service technician. Error code/symptom FRU/action 201-XXX-Y34 (Multiple DIMM failure in Port 2 Bank 4; see "Removing and replacing DIMMs" on page 108) Note: Y = SMP Board [0=Bottom SMP Board; 1=Top SMP Board] 1. Isolate failing DIMM: a. Replace a DIMM in bank with a ″known good″ DIMM. b. Rerun memory diagnostic for the failing bank on failing SMP Board. c. If test fails, mark replaced DIMM as ″good″ DIMM. d. If test passes, mark replaced DIMM as ″bad″ DIMM. e. If DIMM tested is ″bad″, remove it and replace it. f. If DIMM tested is ″good″, do not replace it. 2. Repeat steps 1a through 1f with other DIMMs in failing bank until error is fixed. 3. If error is not fixed, replace SMP Board Y. 202-xxx-00n (Failed System Cache test) 1. Microprocessor n 2. SMP board 203-xxx-xxx (Failed External Cache test) 1. Reload BIOS code. 2. SMP1 board (bottom). 204-198-0xx (Test Aborted) Note: xx=SMP board (01=Bottom SMP board; 10=Top SMP board; 11=Bottom SMP board and Top SMP board) 1. Run Quick Memory Diagnostic All Banks. 2. System BIOS code problem; see PCDR log. 204-210-0xx (Test Failed) Note: xx=SMP board (01=Bottom SMP board; 10=Top SMP board; 11=Bottom SMP board and Top SMP board) 1. Run Quick Memory Diagnostic All Banks. 2. If test runs without failure, update system BIOS code. 3. SMP Board xx. 206-xxx-000 (Failed Diskette Drive test) 1. Rerun test with a different diskette. 2. Diskette drive 3. Media Bay card 215-xxx-000 (Failed CD-ROM test) 1. Rerun test with a different CD. 2. CD-ROM drive 3. Media Bay card 217-xxx-000 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Hard disk drive 1 217-xxx-001 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Hard disk drive 2 217-xxx-002 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Hard disk drive 3 217-xxx-003 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Hard disk drive 4 217-xxx-004 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. Hard disk drive 5 222 xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide