Note: See Chapter 8, "Parts listing, Type 8870," on page 249 to determine which components are replaceable by the customer, and which components should be replaced by an IBM field service technician. Error code/symptom FRU/action 180-361-003 (Failed Fan LED test) 1. Fan 2. I/O board 201-xxx-Ynn (failed Memory Test; see 1. Replace DIMM nn [nn = 1-16] "Removing and replacing DIMMs" on page 108) 2. Replace SMP Board Y [Y = 0-1] Note: nn = DIMM 1-16 [Port 1: DIMMs 1-8; Port 2: DIMMs 9-16]; Y = SMP Board [0=Bottom SMP Board; 1=Top SMP Board] 201-XXX-Y21 (Multiple DIMM failure in Port 1 Bank 1; see "Removing and replacing DIMMs" on page 108) Note: Y = SMP Board [0=Bottom SMP Board; 1=Top SMP Board] 1. Isolate failing DIMM: a. Replace a DIMM in bank with a ″known good″ DIMM. b. Rerun memory diagnostic for the failing bank on failing SMP Board. c. If test fails, mark replaced DIMM as ″good″ DIMM. d. If test passes, mark replaced DIMM as ″bad″ DIMM. e. If DIMM tested is ″bad″, remove it and replace it. f. If DIMM tested is ″good″, do not replace it. 2. Repeat steps 1a through 1f with other DIMMs in failing bank until error is fixed. 3. If error is not fixed, replace SMP Board Y. 201-XXX-Y22 (Multiple DIMM failure in Port 1 Bank 2; see "Removing and replacing DIMMs" on page 108) Note: Y = SMP Board [0=Bottom SMP Board; 1=Top SMP Board] 1. Isolate failing DIMM: a. Replace a DIMM in bank with a ″known good″ DIMM. b. Rerun memory diagnostic for the failing bank on failing SMP Board. c. If test fails, mark replaced DIMM as ″good″ DIMM. d. If test passes, mark replaced DIMM as ″bad″ DIMM. e. If DIMM tested is ″bad″, remove it and replace it. f. If DIMM tested is ″good″, do not replace it. 2. Repeat steps 1a through 1f with other DIMMs in failing bank until error is fixed. 3. If error is not fixed, replace SMP Board Y. 201-XXX-Y23 (Multiple DIMM failure in Port 1 Bank 3; see "Removing and replacing DIMMs" on page 108) Note: Y = SMP Board [0=Bottom SMP Board; 1=Top SMP Board] 1. Isolate failing DIMM: a. Replace a DIMM in bank with a ″known good″ DIMM. b. Rerun memory diagnostic for the failing bank on failing SMP Board. c. If test fails, mark replaced DIMM as ″good″ DIMM. d. If test passes, mark replaced DIMM as ″bad″ DIMM. e. If DIMM tested is ″bad″, remove it and replace it. f. If DIMM tested is ″good″, do not replace it. 2. Repeat steps 1a through 1f with other DIMMs in failing bank until error is fixed. 3. If error is not fixed, replace SMP Board Y. 220 xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide