Oki ML591 MICROLINE Reference Manual - Page 104
Set/Reset Graphics Mode Command Epson, Print Raster Graphics Command Epson
View all Oki ML591 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
Parameters Ln and Hn Parameters Ln and Hn are used to designate the number of bytes to follow in the subsequent parameters, where Number of Bytes = Ln + (Hn x 256) Ln and Hn can have any value from 0 to 255 decimal. Generally, Ln is set to 1 and Hn is set to 0. Parameter Pn Parameter Pn sets the graphics mode. It can have a hexadecimal value of 01 or 31. Note: To cancel the graphics mode, enter the ESC @ command. Set/Reset Graphics Mode Command (Epson) ߜ ML390 Turbo, ML391 Turbo Function Engage Raster Graphics Mode Disengage Raster Graphics Mode ASCII ESC DLE G n 1 ESC DLE G n 0 Dec 27 16 71 n 49 27 16 71 n 48 Hex 1B 10 47 n 31 1B 10 47 n 30 Use this command to engage and disengage the graphics mode. Parameter n This parameter determines how this command is handled: n = 0: Command invalid n = 1: data valid n > 1: data valid; data that follows is discarded after the command has been executed. Print Raster Graphics Command (Epson) ߜ ML390 Turbo, ML391 Turbo ߜ ML590, ML591 Function Print Raster Graphics ASCII ESC . Pc Pv Ph Pm Ln Hn [data] Dec 27 46 Pc Pv Ph Pm Ln Hn [data] Hex 1B 2E Pc Pv Ph Pm Ln Hn [data] Use this command to print bit-image graphics horizontally. Parameter Pc Parameter Pc sets the mode: Pc = 0: Full Graphics Mode Pc = 1: Compressed Mode 66 Chapter 7: Graphics Commands for 24-Pin Printers