HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 100
Invalid DIMM detected. Probable Cause: Invalid DIMM data found. Recommended
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
14455 Warning 14456 Warning 14459 Warning 14460 Warning 14463 Warning 14464 Warning 14465 Warning 14466 Warning 14467 Warning 14469 Warning 14470 Warning 14471 Warning DIMM rank mismatch or rank not found during memory initialization. Probable Cause: The DIMM rank data is invalid or does not match with the other DIMM pair. Recommended Action: The first action will be to reseat the DIMM. If problem persists, replace DIMM with supported DIMM type (see Service Guide). If problem still continues to exist, contact support. WBEM EventID: 9882. WBEM ProviderName: FPL_IndicationProvider. Unable to aquire communications link to scalable memory buffer (SMB). Probable Cause: Failed to acquire communication link to scalable memory buffer (SMB). Recommended Action: The first action will be to replace the CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9883. WBEM ProviderName: FPL_IndicationProvider. Failed outband read access to scalable memory buffer (SMB) due to timeout. Probable Cause: Failed outband read access to scalable memory buffer (SMB) due to timeout. Recommended Action: The first action will be to replace the CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9878. WBEM ProviderName: FPL_IndicationProvider. Failed outband write access to scalable memory buffer (SMB) due to timeout. Probable Cause: Failed outband write access to memory controller due to timeout. Recommended Action: The first action will be to replace the CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9879. WBEM ProviderName: FPL_IndicationProvider. Inband access to memory controller timed out. Probable Cause: Failed inband access to scalable memory buffer (SMB) due to timeout. Recommended Action: The first action will be to replace the CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9890. WBEM ProviderName: FPL_IndicationProvider. Frequency ratio for DIMM is incompatible. Probable Cause: Memory frequency ratio is not supported by system platform. Recommended Action: The first action will be to reseat the DIMM. If problem persists, replace DIMM with supported DIMM type (see Service Guide). If problem still continues to exist, contact support. WBEM EventID: 9891. WBEM ProviderName: FPL_IndicationProvider. Reached unexpected code paths in memory initialization code. Probable Cause: Reached unexpected code paths in memory initialization code. Recommended Action: Ensure SFW component is at supported level. If problem persists, contact support. WBEM EventID: 9892. WBEM ProviderName: FPL_IndicationProvider. LAI expander detected. Probable Cause: Unsupported memory LAI expander detected. Recommended Action: Contact support. WBEM EventID: 9893. WBEM ProviderName: FPL_IndicationProvider. Invalid DIMM detected. Probable Cause: Invalid DIMM data found. Recommended Action: The first action will be to reseat the DIMM. If that does not solve the issue, replace DIMM with supported DIMM type (See Service Guide). If problem still continues to exist, contact support. WBEM EventID: 9897. WBEM ProviderName: FPL_IndicationProvider. DDR calibration for commands failed. Probable Cause: DDR calibration of command failed. Recommended Action: The first action will be to check SEL for de-allocated DIMM(s). Reseat and/or replace the DIMM(s). If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9896. WBEM ProviderName: FPL_IndicationProvider. DDR channel training failed. Probable Cause: DDR3 training failure. Recommended Action: The first action will be to check SEL for de-allocated DIMM(s). Reseat and/or replace the DIMM(s). If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9895. WBEM ProviderName: FPL_IndicationProvider. Pre-initialization of memory controller failed. Probable Cause: Failed to initialize internal communications engine on CPU. Recommended Action: The first action will be to check SEL for de-allocated DIMM(s). Reseat and/or replace the DIMM(s). If that does not solve the issue, replace CPU. If problem still continues to exist, replace the system board. WBEM EventID: 9894. WBEM ProviderName: FPL_IndicationProvider. 100 WBEM Provider Event Tables