HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 85

is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI

Page 85 highlights

12144 Warning 12149 Error 12150 Error 12153 Warning 12155 Error 12156 Warning 12157 Warning 12159 Warning 12160 Warning 12161 Warning 12162 Warning The MP has re-gained lan communication with the UPS. WBEM EventID: 6834. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The data value is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor ISR. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6570. WBEM ProviderName: FPL_IndicationProvider. Double chip sparing has been invoked. Probable Cause: System firmware has detected and corrected memory errors. Double chip sparing has been invoked to help mitigate this condition. Recommended Action: On the next reboot, system firmware will test the specified memory components, and may take them offline if the errors persist. contact your HP support representative to check the specified memory components at your next scheduled downtime. WBEM EventID: 6572. WBEM ProviderName: FPL_IndicationProvider. External clock cable has been removed from the CPU cabinet. The data field contains the physical location of the cabinet. Probable Cause: External clock cable has been removed from the CPU cabinet. Recommended Action: Check external clock cable. WBEM EventID: 6575. WBEM ProviderName: FPL_IndicationProvider. System Fabric encountered a link error after opening up the fabric link. Probable Cause: Fabric link errors were encountered. Recommended Action: Collect IPMI event logs. Contact your HP Support Representative to check the health of the system fabric. WBEM EventID: 6576. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32) | 1. Probable Cause: Fatal errors are present on the cell to crossbar links. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6577. WBEM ProviderName: FPL_IndicationProvider. System firmware encountered fabric problems. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Errors occurred while collecting error data from a fabric link. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6579. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Fatal errors are present on a cell to crossbar link. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6580. WBEM ProviderName: FPL_IndicationProvider. The operating system has recovered from a PCI error. Probable Cause: If the data word is not 0x0000000400000000, then the problem is most likely with the PCI card. If the value of the data word is 0x0000000400000000, then check event log with keyword PCI_ERROR_STATUS. If PCI_ERROR_STATUS > 1, then the problem is in the connection between System Bus Adapter and Lower Bus Adapter. If PCI_ERROR_STATUS = 1, then the problem is in the Lower Bus Adapter. WBEM EventID: 6910. WBEM ProviderName: FPL_IndicationProvider. The operating system has recovered from a PCI error. Probable Cause: See event with keyword PCI_LBA_DEV_SPEC_1. WBEM EventID: 6911. WBEM ProviderName: FPL_IndicationProvider. Platform Events 85

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

The MP has re-gained lan communication with the UPS. WBEM EventID: 6834.
WBEM ProviderName: FPL_IndicationProvider.
Warning
12144
An unrecoverable processor interrupt occurred while in IPF firmware. The data value
is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver,
EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset
applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM
Volume 2. Recommended Action: Provide console log containing register dump to
HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName:
FPL_IndicationProvider.
Error
12149
An unrecoverable processor interrupt occurred while in IPF firmware. The event
data is the processor ISR. Probable Cause: Probable bug in System Firmware, EFI
driver, EFI app or OS loader (prior to OS launch). The event data field contains the
IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the
Intel ASDM Volume 2. Recommended Action: Provide console log containing register
dump to HP Customer Engineer. WBEM EventID: 6570. WBEM ProviderName:
FPL_IndicationProvider.
Error
12150
Double chip sparing has been invoked. Probable Cause: System firmware has detected
and corrected memory errors. Double chip sparing has been invoked to help mitigate
this condition. Recommended Action: On the next reboot, system firmware will test
the specified memory components, and may take them offline if the errors persist.
contact your HP support representative to check the specified memory components
at your next scheduled downtime. WBEM EventID: 6572. WBEM ProviderName:
FPL_IndicationProvider.
Warning
12153
External clock cable has been removed from the CPU cabinet. The data field contains
the physical location of the cabinet. Probable Cause: External clock cable has been
removed from the CPU cabinet. Recommended Action: Check external clock cable.
WBEM EventID: 6575. WBEM ProviderName: FPL_IndicationProvider.
Error
12155
System Fabric encountered a link error after opening up the fabric link. Probable
Cause: Fabric link errors were encountered. Recommended Action: Collect IPMI
event logs. Contact your HP Support Representative to check the health of the system
fabric. WBEM EventID: 6576. WBEM ProviderName: FPL_IndicationProvider.
Warning
12156
Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) |
(crossbar 32) | 1. Probable Cause: Fatal errors are present on the cell to crossbar links.
Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6577. WBEM
ProviderName: FPL_IndicationProvider.
Warning
12157
System firmware encountered fabric problems. Data Field: (crossbar port 44) |
(crossbar 32). Probable Cause: Errors occurred while collecting error data from a
fabric link. Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6579. WBEM
ProviderName: FPL_IndicationProvider.
Warning
12159
Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) |
(crossbar 32). Probable Cause: Fatal errors are present on a cell to crossbar link.
Recommended Action: Collect IPMI Event logs. Contact your HP Support
Representative to check the fabric subsystem health. WBEM EventID: 6580. WBEM
ProviderName: FPL_IndicationProvider.
Warning
12160
The operating system has recovered from a PCI error. Probable Cause: If the data
word is not 0x0000000400000000, then the problem is most likely with the PCI card.
If the value of the data word is 0x0000000400000000, then check event log with
keyword PCI_ERROR_STATUS. If PCI_ERROR_STATUS > 1, then the problem is in
the connection between System Bus Adapter and Lower Bus Adapter. If
PCI_ERROR_STATUS = 1, then the problem is in the Lower Bus Adapter. WBEM
EventID: 6910. WBEM ProviderName: FPL_IndicationProvider.
Warning
12161
The operating system has recovered from a PCI error. Probable Cause: See event
with keyword PCI_LBA_DEV_SPEC_1. WBEM EventID: 6911. WBEM ProviderName:
FPL_IndicationProvider.
Warning
12162
Platform Events
85