HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 85
is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
12144 Warning 12149 Error 12150 Error 12153 Warning 12155 Error 12156 Warning 12157 Warning 12159 Warning 12160 Warning 12161 Warning 12162 Warning The MP has re-gained lan communication with the UPS. WBEM EventID: 6834. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The data value is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor ISR. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6570. WBEM ProviderName: FPL_IndicationProvider. Double chip sparing has been invoked. Probable Cause: System firmware has detected and corrected memory errors. Double chip sparing has been invoked to help mitigate this condition. Recommended Action: On the next reboot, system firmware will test the specified memory components, and may take them offline if the errors persist. contact your HP support representative to check the specified memory components at your next scheduled downtime. WBEM EventID: 6572. WBEM ProviderName: FPL_IndicationProvider. External clock cable has been removed from the CPU cabinet. The data field contains the physical location of the cabinet. Probable Cause: External clock cable has been removed from the CPU cabinet. Recommended Action: Check external clock cable. WBEM EventID: 6575. WBEM ProviderName: FPL_IndicationProvider. System Fabric encountered a link error after opening up the fabric link. Probable Cause: Fabric link errors were encountered. Recommended Action: Collect IPMI event logs. Contact your HP Support Representative to check the health of the system fabric. WBEM EventID: 6576. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32) | 1. Probable Cause: Fatal errors are present on the cell to crossbar links. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6577. WBEM ProviderName: FPL_IndicationProvider. System firmware encountered fabric problems. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Errors occurred while collecting error data from a fabric link. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6579. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Fatal errors are present on a cell to crossbar link. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6580. WBEM ProviderName: FPL_IndicationProvider. The operating system has recovered from a PCI error. Probable Cause: If the data word is not 0x0000000400000000, then the problem is most likely with the PCI card. If the value of the data word is 0x0000000400000000, then check event log with keyword PCI_ERROR_STATUS. If PCI_ERROR_STATUS > 1, then the problem is in the connection between System Bus Adapter and Lower Bus Adapter. If PCI_ERROR_STATUS = 1, then the problem is in the Lower Bus Adapter. WBEM EventID: 6910. WBEM ProviderName: FPL_IndicationProvider. The operating system has recovered from a PCI error. Probable Cause: See event with keyword PCI_LBA_DEV_SPEC_1. WBEM EventID: 6911. WBEM ProviderName: FPL_IndicationProvider. Platform Events 85