HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 57

Invalid data read from a CPU module's Processor Information ROM. Probable Cause

Page 57 highlights

8839 8842 8855 8857 8858 8859 8860 8861 8864 8865 8872 8877 8882 8883 8906 8940 Error Warning Error Warning Warning Warning Warning Warning Warning Warning Error Warning Warning Warning Warning Error The cell will not join the PD. Probable Cause: Broken hardware was detected and the cell integration policy combined to cause the cell to not join the PD. Recommended Action: Fix the broken hardware or change the policy using parmgr. If assistance is required, contact the HP Support Center. WBEM EventID: 833. WBEM ProviderName: FPL_IndicationProvider. The error context in NVM was corrupt. Probable Cause: NVM is corrupted. Recommended Action: Check for other errors in the system first. Invalidate NVM and retry boot. Get the latest firmware release. WBEM EventID: 834. WBEM ProviderName: FPL_IndicationProvider. Firmware encountered a problem trying to initialize. Probable Cause: Examine the related event that failed and correct that problem. WBEM EventID: 837. WBEM ProviderName: FPL_IndicationProvider. This means that all the cpus in the cell did not show up. Probable Cause: This will result in the cell stepping independently to collect its logs and resting itself. WBEM EventID: 838. WBEM ProviderName: FPL_IndicationProvider. This means that all the cells did not rendezvous during the PD rendezvous. Probable Cause: The cells will reset themselves. WBEM EventID: 839. WBEM ProviderName: FPL_IndicationProvider. The FW tree sanity check failed during the MCA error processing. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 840. WBEM ProviderName: FPL_IndicationProvider. This means that the registry sanity check failed during MCA error handling. Probable Cause: The cells will independently log errors and reset. WBEM EventID: 841. WBEM ProviderName: FPL_IndicationProvider. This means that MCA occurred while OS_MCA was performing error recovery. Probable Cause: The cells will log information and reset. WBEM EventID: 842. WBEM ProviderName: FPL_IndicationProvider. One of the BT errors occurred that results in abandoning memory dump. Probable Cause: A machine check has occurred and cells have not rendezvoused. Recommended Action: Cells will reset themselves. WBEM EventID: 843. WBEM ProviderName: FPL_IndicationProvider. The firmware tree is not complete and hence there will be no PD rendezvous. Probable Cause: The cell will log errors and reset. WBEM EventID: 844. WBEM ProviderName: FPL_IndicationProvider. ACPI configuration mismatch across cells in the partition. Probable Cause: Set the ACPI configuration parameter again to ensure that all cells have a consistent value. WBEM EventID: 845. WBEM ProviderName: FPL_IndicationProvider. Invalid data read from a CPU module's Processor Information ROM. Probable Cause: The CPU module's Processor Information ROM is unprogrammed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module pointed to by the physical location portion of this event. WBEM EventID: 849. WBEM ProviderName: FPL_IndicationProvider. Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProvider. Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM EventID: 851. WBEM ProviderName: FPL_IndicationProvider. An Error occurred trying to notify the MP of the attempted reset. Probable Cause: The MP is not functioning or the PDHC cannot communicate with it. Reset the MP. WBEM EventID: 858. WBEM ProviderName: FPL_IndicationProvider. Cell has been disabled by the PDHC because no CPU modules were found. Probable Cause: No CPU modules are installed. Recommended Action: Install CPU modules on the Cell. WBEM EventID: 866. WBEM ProviderName: FPL_IndicationProvider. Platform Events 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

The cell will not join the PD. Probable Cause: Broken hardware was detected and
the cell integration policy combined to cause the cell to not join the PD. Recommended
Action: Fix the broken hardware or change the policy using parmgr. If assistance is
required, contact the HP Support Center. WBEM EventID: 833. WBEM ProviderName:
FPL_IndicationProvider.
Error
8839
The error context in NVM was corrupt. Probable Cause: NVM is corrupted.
Recommended Action: Check for other errors in the system first. Invalidate NVM
and retry boot. Get the latest firmware release. WBEM EventID: 834. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8842
Firmware encountered a problem trying to initialize. Probable Cause: Examine the
related event that failed and correct that problem. WBEM EventID: 837. WBEM
ProviderName: FPL_IndicationProvider.
Error
8855
This means that all the cpus in the cell did not show up. Probable Cause: This will
result in the cell stepping independently to collect its logs and resting itself. WBEM
EventID: 838. WBEM ProviderName: FPL_IndicationProvider.
Warning
8857
This means that all the cells did not rendezvous during the PD rendezvous. Probable
Cause: The cells will reset themselves. WBEM EventID: 839. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8858
The FW tree sanity check failed during the MCA error processing. Probable Cause:
The cells will independently log errors and reset. WBEM EventID: 840. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8859
This means that the registry sanity check failed during MCA error handling. Probable
Cause: The cells will independently log errors and reset. WBEM EventID: 841. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8860
This means that MCA occurred while OS_MCA was performing error recovery.
Probable Cause: The cells will log information and reset. WBEM EventID: 842. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8861
One of the BT errors occurred that results in abandoning memory dump. Probable
Cause: A machine check has occurred and cells have not rendezvoused. Recommended
Action: Cells will reset themselves. WBEM EventID: 843. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8864
The firmware tree is not complete and hence there will be no PD rendezvous. Probable
Cause: The cell will log errors and reset. WBEM EventID: 844. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8865
ACPI configuration mismatch across cells in the partition. Probable Cause: Set the
ACPI configuration parameter again to ensure that all cells have a consistent value.
WBEM EventID: 845. WBEM ProviderName: FPL_IndicationProvider.
Error
8872
Invalid data read from a CPU module's Processor Information ROM. Probable Cause:
The CPU module's Processor Information ROM is unprogrammed. Recommended
Action: Contact HP support personnel to troubleshoot the CPU module pointed to
by the physical location portion of this event. WBEM EventID: 849. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8877
Invalid parameter when setting cpu frequency ratios. Probable Cause: Specify a valid
parameter. WBEM EventID: 2444. WBEM ProviderName: FPL_IndicationProvider.
Warning
8882
Option block in nvram has a checksum error. Probable Cause: Clear NVRAM. WBEM
EventID: 851. WBEM ProviderName: FPL_IndicationProvider.
Warning
8883
An Error occurred trying to notify the MP of the attempted reset. Probable Cause:
The MP is not functioning or the PDHC cannot communicate with it. Reset the MP.
WBEM EventID: 858. WBEM ProviderName: FPL_IndicationProvider.
Warning
8906
Cell has been disabled by the PDHC because no CPU modules were found. Probable
Cause: No CPU modules are installed. Recommended Action: Install CPU modules
on the Cell. WBEM EventID: 866. WBEM ProviderName: FPL_IndicationProvider.
Error
8940
Platform Events
57