HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 28
Error writing to Fabric. Probable Cause: Bad hardware. WBEM EventID: 362. WBEM
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
5376 5380 5383 5403 5404 5405 5406 5407 5408 5411 5416 5417 5418 5419 5420 5432 5438 Error Error Error Error Warning Warning Warning Error Error Error Error Error Error Warning Error Error Warning Reporting cell was not included in the global cell set. Probable Cause: Fabric problem, Connection problem or timing problem. Reset the PD. WBEM EventID: 356. WBEM ProviderName: FPL_IndicationProvider. No Core Cell can be selected in the PD. Probable Cause: No cells have a functioning core IO card. Add a core IO card to a cell in the PD and reset. WBEM EventID: 357. WBEM ProviderName: FPL_IndicationProvider. Firmware was unable to notify utilities of the core cell number. Probable Cause: Communication with utilities is broken. Check for earlier errors or NVRAM problems. WBEM EventID: 358. WBEM ProviderName: FPL_IndicationProvider. Fabric code unable to find a needed service provider. Probable Cause: The registry is corrupt or the ROM is incomplete. WBEM EventID: 359. WBEM ProviderName: FPL_IndicationProvider. Error in a fabric Port. Probable Cause: Reset. WBEM EventID: 360. WBEM ProviderName: FPL_IndicationProvider. Parity error detected on read from fabric. Probable Cause: Hardware problem. Check connections and reset. WBEM EventID: 361. WBEM ProviderName: FPL_IndicationProvider. Error writing to Fabric. Probable Cause: Bad hardware. WBEM EventID: 362. WBEM ProviderName: FPL_IndicationProvider. Crossbar slices are out of rev with each other. Probable Cause: Bad hardware configuration, different revisions of crossbars are installed. Recommended Action: Check crossbar revisions and ensure all installed crossbar revisions are the same. Replace the crossbar that is not in rev with the others. WBEM EventID: 363. WBEM ProviderName: FPL_IndicationProvider. Crossbar slices are configured poorly. Probable Cause: Fatal configuration. Reconfigure the hardware. WBEM EventID: 364. WBEM ProviderName: FPL_IndicationProvider. A CPU has taken over for the monarch CPU. Probable Cause: The previous monarch may be suspect. WBEM EventID: 365. WBEM ProviderName: FPL_IndicationProvider. Sram cannot be used on the cell. Probable Cause: SRAM cannot be located or used on the cell board. Replace the cell board. WBEM EventID: 366. WBEM ProviderName: FPL_IndicationProvider. The dillon hardware cannot be located. Probable Cause: ROM is corrupt. Replace the rom or reprogram flash. WBEM EventID: 367. WBEM ProviderName: FPL_IndicationProvider. A required piece of PDH bus hardware cannot be contacted. Probable Cause: Verify all connections of PDH bus components or replace the cell board. WBEM EventID: 368. WBEM ProviderName: FPL_IndicationProvider. Error: PCI Buses are configured for multiple speeds. Probable Cause: A PCI card is configured with mixed speeds. Recommended Action: Correct the configuration problem. WBEM EventID: 2420. WBEM ProviderName: FPL_IndicationProvider. The bus depth was exceeded during IO probing. Probable Cause: Too many PCI bridge cards are configured in single PCI segment mode. Recommended Action: Reconfigure PCI cards and remove some of the bridge devices. WBEM EventID: 2421. WBEM ProviderName: FPL_IndicationProvider. A Timeout occurred during RI initialization. The CSR is in the data field. The alert level will vary. Probable Cause: Hardware problem such as cable connect error or bad cables. Recommended Action: Correct the hardware problem and re-boot. WBEM EventID: 2422. WBEM ProviderName: FPL_IndicationProvider. SuperIO has been detected in slot. Probable Cause: SuperIO has been detected in the PCI slot. Recommended Action: No action required, information only. WBEM EventID: 2423. WBEM ProviderName: FPL_IndicationProvider. 28 WBEM Provider Event Tables