HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 13
Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3.
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
730 Error The BMC firmware did not detect the system firmware boot. Probable Cause: Possible Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3. Processor is in reset or is not properly seated in system 4. An unsupported processor was inserted in system 5. Communication with BMC is impaired. Recommended Action: To correct the problem, try the following: 1. Validate that processors are supported in this system. 2. Verify that processors are seated properly in system. 3. Check if system has booted (only a communication problem. - future events will also be lost.) 4. Attempt a system reset, INIT, and/or A/C cycle to clear the problem. 5. Update system firmware again if necessary. WBEM EventID: 132. WBEM ProviderName: SEL02_IndicationProvider. 730 Error The BMC firmware did not detect the system firmware boot. Probable Cause: Possible Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3. Processor is in reset or is not properly seated in system 4. An unsupported processor was inserted in system 5. Communication with BMC is impaired. Recommended Action: To correct the problem, try the following: 1. Validate that processors are supported in this system. 2. Verify that processors are seated properly in system. 3. Check if system has booted (only a communication problem. - future events will also be lost.) 4. Attempt a system reset, INIT, and/or A/C cycle to clear the problem. 5. Update system firmware again if necessary. WBEM EventID: 132. WBEM ProviderName: SEL02_IndicationProvider. 731 Error A/C Power failed, disconnected, or out of range. Probable Cause: The input power to the supply has failed or gone out of range. Or the input cord has been disconnected. Recommended Action: Check the power cord or source voltage. WBEM EventID: 154. WBEM ProviderName: SEL02_IndicationProvider. 731 Error A/C Power failed, disconnected, or out of range. Probable Cause: The input power to the supply has failed or gone out of range. Or the input cord has been disconnected. Recommended Action: Check the power cord or source voltage. WBEM EventID: 154. WBEM ProviderName: SEL02_IndicationProvider. 732 Warning The power supply sensors detect a possible problem. Probable Cause: The power supply fan(s) is slowing. Recommended Action: Check power supply fan(s). WBEM EventID: 138. WBEM ProviderName: SEL02_IndicationProvider. 732 Warning The power supply sensors detect a possible problem. Probable Cause: The power supply fan(s) is slowing. Recommended Action: Check power supply fan(s). WBEM EventID: 138. WBEM ProviderName: SEL02_IndicationProvider. 733 Warning Cooling unit warning. Probable Cause: The Cooling Unit may be running properly now, but it was detected in a degraded state. It may need to be replaced in the future. Recommended Action: Continue to monitor unit and contact HP support to determine appropriate action. WBEM EventID: 157. WBEM ProviderName: SEL02_IndicationProvider. 733 Warning Cooling unit warning. Probable Cause: The Cooling Unit may be running properly now, but it was detected in a degraded state. It may need to be replaced in the future. Recommended Action: Continue to monitor unit and contact HP support to determine appropriate action. WBEM EventID: 157. WBEM ProviderName: SEL02_IndicationProvider. 734 Error Cooling unit failure. Probable Cause: A cooling unit has failed. Recommended Action: Replace the indicated cooling unit. WBEM EventID: 158. WBEM ProviderName: SEL02_IndicationProvider. 734 Error Cooling unit failure. Probable Cause: A cooling unit has failed. Recommended Action: Replace the indicated cooling unit. WBEM EventID: 158. WBEM ProviderName: SEL02_IndicationProvider. 735 Warning BMC entering special mode. Probable Cause: BMC entering special mode. The system is not operating in a normal configuration. Some protection features may be disabled in this mode. Recommended Action: The Special Mode must be exited to ensure proper operation of the server. WBEM EventID: 166. WBEM ProviderName: SEL02_IndicationProvider. Platform Events 13