HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 48
Read of EEPROM failed. Probable Cause: The I2C bus into the IO Power Board
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
7836 7842 7845 7846 7849 7855 7856 7858 7863 7864 7865 7866 Warning Warning Error Error Warning Error Error Warning Warning Warning Warning Error IO Fan Failed. Probable Cause: IO Cooling Fan Failed. Recommended Action: Replace IO Fan Module as soon as possible following the IO Fan Module Remove and Replace Procedures. WBEM EventID: 678. WBEM ProviderName: FPL_IndicationProvider. Cabinet Power System is in overload. Probable Cause: A Bulk Power Supply has failed, or, entities were added. Look for one or more BPS_Fail Chassis Codes preceding this one for the actual failures. This code is a warning of possible cabinet unreliability. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 680. WBEM ProviderName: FPL_IndicationProvider. Cabinet Shutdown - Insufficient Blowers. Probable Cause: One blower has failed creating condition N. Before condition N was corrected, another blower in the same cabinet was declared failed. This created the illegal condition of N-1. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 681. WBEM ProviderName: FPL_IndicationProvider. Cabinet Shutdown - Insufficient IO Fans. Probable Cause: One IO fan has failed creating condition N. Before condition N was corrected, another IO fan in the same cabinet failed. This created the illegal condition of N-1. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 682. WBEM ProviderName: FPL_IndicationProvider. IO Expansion Utility Cabinet Fan Failed. Probable Cause: IO Expansion Utility Fan or Fan sensor failure PM failure. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 683. WBEM ProviderName: FPL_IndicationProvider. Watchdog Timer Expired. Probable Cause: The CLU firmware has been reset by the MFG MP command RU. Recommended Action: No action is required. WBEM EventID: 684. WBEM ProviderName: FPL_IndicationProvider. Invalid checksum from EEPROM. Probable Cause: Data corrupted in the named EEPROM. Recommended Action: If this is a single entry, replace the FRU. WBEM EventID: 685. WBEM ProviderName: FPL_IndicationProvider. System Backplane Power Board Fault. Probable Cause: A DC-DC converter on the named power board failed. Recommended Action: Contact HP Support personnel to troubleshoot the problem Caution: The 1.8 volt converters are N+1. The 3.3 volt converters are N+2. If there is a situation where a 1.8 fails at the same time as a 3.3 on a different power board, replace the failed 1.8 board first. WBEM EventID: 686. WBEM ProviderName: FPL_IndicationProvider. Read of EEPROM failed. Probable Cause: The cable from the Utilities Backplane to the Master IO Backplane is bad, or is not properly connected. Recommended Action: Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP Support personnel to troubleshoot the problem. WBEM EventID: 687. WBEM ProviderName: FPL_IndicationProvider. Read of EEPROM failed. Probable Cause: The I2C bus into the IO Power Board EEPROM is bad. Recommended Action: Could possibly be a bent pin on the Master IO Backplane Utilities cable connectors. Check the connectors at each end of the cable for bent or broken pins. Or, it could be a bent pin on the Master IO Backplane where the PCI Cardcage connects. If the MIOB, connectors and cable are good, contact HP Support personnel to troubleshoot the problem. WBEM EventID: 688. WBEM ProviderName: FPL_IndicationProvider. Read of LPM Fault failed. Probable Cause: The cable from the Utilities Backplane to the Master IO Backplane is bad, or is not properly connected. Recommended Action: Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP Support personnel to troubleshoot the problem. WBEM EventID: 689. WBEM ProviderName: FPL_IndicationProvider. IO Power Board Over temperature. Probable Cause: The ambient air is too warm. Recommended Action: Check the Error Log for other Overtemp Warnings to confirm the environmental problem. WBEM EventID: 690. WBEM ProviderName: FPL_IndicationProvider. 48 WBEM Provider Event Tables