HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 111

PFM Events

Page 111 highlights

Event ID Event Severity Event Description 1002 Warning The IPMI driver read a registry parameter that was invalid, the driver used a default value for the registry parameter HKLM\SYSTEM\CurrentControlSet\Control\IPMI\%2. 1003 Error The IPMI device driver attempted to communicate with the IPMI BMC device during device creation. However the communication failed due to a timeout. Either the configured timeouts are too small and the IPMI BMC device responses take longer than the timeouts or the BMC has a technical fault. You can increase the timeouts associated with the IPMI device driver. 1004 Error The IPMI device driver attempted to communicate with the IPMI BMC device during normal operation. However the communication failed due to a timeout. You can try increasing the timeouts associated with the IPMI device driver located in the registry at HKLM\SYSTEM\CurrentControlSet\Control\IPMI\CommandWaitTimeoutPeriod, between 5000000 (5 seconds) to 30000000 (30 seconds), the default is 10 seconds. 2000 Information \Device\CpqHlth, The Hewlett Packard IPMI device driver was loaded. 2001 Error The Hewlett Packard IPMI device driver could not load. NTSTATUS return code is shown in data field. Make sure you have the latest version of the driver. 2002 Warning The IPMI device driver could not open the IML soft log in the windows registry: %2. Make sure HP Insight Management Agents or HP Insight Management WBEM Providers are installed. PFM Events Source in Windows Event Log: HpPfmSvcEx Event ID Event Severity Event Description 1 Warning A Corrected Machine Check (or Corrected Platform Error) error of an unknown variety was observed by the PreFail Monitor. This error was corrected and no action is necessary, but if this condition repeats contact HP for support guidance. 1 Warning HP PFM has detected an invalid HP PFM rules file. As the result, default monitoring threshold values are being used. Please contact HP support team to solve this problem. 2 Information HP PFM service detected the DIMM module in %s has been added. 2 Information HP PFM service detected the DIMM module in %s has been removed. 2 Information HP PFM service detected the DIMM module in %s has been replaced. 2 Information HP PFM has detected a module replacement: The DIMM %s has been replaced. The serial number of the older module was %s and the serial number of the newer is %s. 2 Information HP PFM service detected the CPU module in %s has been added. 2 Information HP PFM service detected the CPU module in %s has been removed. 2 Information HP PFM service detected the CPU module in %s has been replaced. 2 Information HP PFM has detected a module replacement: The CPU %s has been replaced. The serial number of the older module was %s and the serial number of the newer is %s. 2 Information The Predictive Failure Monitor sub-service version %s has started. 2 Information The Predictive Failure Monitor sub-service has stopped. 3 Error PFM cannot initialize WMI interface. Please check WMI service status. PFM Events 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
The IPMI driver read a registry parameter that was invalid, the driver used a default
value for the registry parameter
HKLM\SYSTEM\CurrentControlSet\Control\IPMI\%2.
Warning
1002
The IPMI device driver attempted to communicate with the IPMI BMC device during
device creation. However the communication failed due to a timeout. Either the
configured timeouts are too small and the IPMI BMC device responses take longer
than the timeouts or the BMC has a technical fault. You can increase the timeouts
associated with the IPMI device driver.
Error
1003
The IPMI device driver attempted to communicate with the IPMI BMC device during
normal operation. However the communication failed due to a timeout. You can try
increasing the timeouts associated with the IPMI device driver located in the registry
at
HKLM\SYSTEM\CurrentControlSet\Control\IPMI\CommandWaitTimeoutPeriod,
between 5000000 (5 seconds) to 30000000 (30 seconds), the default is 10 seconds.
Error
1004
\Device\CpqHlth, The Hewlett Packard IPMI device driver was loaded.
Information
2000
The Hewlett Packard IPMI device driver could not load. NTSTATUS return code is
shown in data field. Make sure you have the latest version of the driver.
Error
2001
The IPMI device driver could not open the IML soft log in the windows registry: %2.
Make sure HP Insight Management Agents or HP Insight Management WBEM
Providers are installed.
Warning
2002
PFM Events
Source in Windows Event Log:
HpPfmSvcEx
Event Description
Event
Severity
Event ID
A Corrected Machine Check (or Corrected Platform Error) error of an unknown
variety was observed by the PreFail Monitor. This error was corrected and no action
is necessary, but if this condition repeats contact HP for support guidance.
Warning
1
HP PFM has detected an invalid HP PFM rules file. As the result, default monitoring
threshold values are being used. Please contact HP support team to solve this problem.
Warning
1
HP PFM service detected the DIMM module in %s has been added.
Information
2
HP PFM service detected the DIMM module in %s has been removed.
Information
2
HP PFM service detected the DIMM module in %s has been replaced.
Information
2
HP PFM has detected a module replacement: The DIMM %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Information
2
HP PFM service detected the CPU module in %s has been added.
Information
2
HP PFM service detected the CPU module in %s has been removed.
Information
2
HP PFM service detected the CPU module in %s has been replaced.
Information
2
HP PFM has detected a module replacement: The CPU %s has been replaced. The
serial number of the older module was %s and the serial number of the newer is %s.
Information
2
The Predictive Failure Monitor sub-service version %s has started.
Information
2
The Predictive Failure Monitor sub-service has stopped.
Information
2
PFM cannot initialize WMI interface. Please check WMI service status.
Error
3
PFM Events
111