HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 93
CPU. Recommended Action: Update SFW. If the failure persists on the same CPU
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
13294 Error 13295 Error 13296 Error 13297 Error 13298 Error 13299 Error 13300 Error 13301 Error 13302 Error 13303 Warning 13331 Error 13412 Error 13413 Error ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the slot AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8543. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the Platfrom AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8544. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the HPET AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8525. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the IPMI AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8528. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the Power Management AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8537. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the CPU AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8523. WBEM ProviderName: FPL_IndicationProvider. ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI subsystem could not find the memory AML identifier while parsing the DSDT table. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8532. WBEM ProviderName: FPL_IndicationProvider. ACPI failed to set its tables. Probable Cause: The ACPI driver in firmware failed to set the tables. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8542. WBEM ProviderName: FPL_IndicationProvider. The ACPI subsystem failed to load the DSDT table from flash device. Probable Cause: The ACPI subsystem failed to load the DSDT table from flash device. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8529. WBEM ProviderName: FPL_IndicationProvider. The ACPI subsystem failed to load the SSDT table from the flash device. Probable Cause: The ACPI could not load the SSDT table from the flash device. Recommended Action: Ensure SFW component is at supported level. WBEM EventID: 8531. WBEM ProviderName: FPL_IndicationProvider. SFW ROM versions across the partition are mismatched. Probable Cause: One or more processor System Firmware ROM version is mismatched with the Monarch CPU. Recommended Action: Update SFW. If the failure persists on the same CPU, replace the system board. WBEM EventID: 8103. WBEM ProviderName: FPL_IndicationProvider. The iLO peer to peer LAN communication between MMP and AMP was lost. Probable Cause: The iLO peer to peer LAN communication between a Monarch MP (MMP) and an Auxilary MP (AMP) has been lost. Recommended Action: The management system will attempt to repair itself. If the management system does not recover refer to the Service Guide to determine how to reset iLO without a user interface. WBEM EventID: 9862. WBEM ProviderName: FPL_IndicationProvider. The iLO peer to peer LAN communication between MMP and AMP was not established. Probable Cause: The iLO peer to peer LAN communication between Monarch MP (MMP) and an Auxilarly MP (AMP) could not be established. Recommended Action: The management system will attempt to repair itself. If the management system does not recover refer to the Service Guide to determine how to reset iLO without a user interface. WBEM EventID: 9863. WBEM ProviderName: FPL_IndicationProvider. Platform Events 93