HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 60
An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
9485 9486 9487 9488 9489 9490 9491 9492 9493 9494 9495 9496 9497 9652 Error Error Error Error Error Error Error Error Error Error Error Error Warning Warning The SBA failed and the cell has no I/O. Probable Cause: Cannot configure IO on the cell, probably due to previous errors. Recommended Action: Correct the hardware/software problem indicated by previous errors. WBEM EventID: 962. WBEM ProviderName: FPL_IndicationProvider. The system firmware had an error with the structured error handling mechanism. Probable Cause: Either there is an error in the system firmware or the system firmware has exhausted all resources. Recommended Action: Invalidate NVM or check for newer version of system firmware. WBEM EventID: 963. WBEM ProviderName: FPL_IndicationProvider. Not enough malloc resources for I/O structure error handling. Probable Cause: Either invalidate NVM or check for a new version of system firmware. WBEM EventID: 964. WBEM ProviderName: FPL_IndicationProvider. Unable to create entry for I/O structure error handling. Probable Cause: This is a system firmware error, either invalidate NVM or check for a newer version of system firmware. WBEM EventID: 965. WBEM ProviderName: FPL_IndicationProvider. Unable to bind services for I/O structure exception handling. Probable Cause: This is a system firmware error. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 966. WBEM ProviderName: FPL_IndicationProvider. Error initializing the I/O structure exception handling services. Probable Cause: This is a system firmware error. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 967. WBEM ProviderName: FPL_IndicationProvider. Error initializing structured I/O exception data structures. Probable Cause: This is a system firmware error, there is a conflict with system resources. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 968. WBEM ProviderName: FPL_IndicationProvider. The I/O exception context has an error. Probable Cause: This is a system firmware error. Reset the system, invalidate NVM and reset the system, or check for a newer version of the system firmware. WBEM EventID: 969. WBEM ProviderName: FPL_IndicationProvider. Error creating the internal data and services for the SBA. Probable Cause: This is a system firmware error. Reset the system; invalidate NVM and reset the system; or check for a newer version of system firmware. WBEM EventID: 970. WBEM ProviderName: FPL_IndicationProvider. Error attaching the services to the SBA internal data structures. Probable Cause: This is a system firmware error. Reset the partition; invalidate NVM on the reporting cell and reset the system; or check for a newer version of system firmware. WBEM EventID: 971. WBEM ProviderName: FPL_IndicationProvider. Error initializing the internal SBA data and services. Probable Cause: This is a system firmware error. Reset the partition; invalidate NVM on the reporting cell and reset the partition; or check for newer system firmware. WBEM EventID: 972. WBEM ProviderName: FPL_IndicationProvider. The SBA type is unknown to the system firmware. Probable Cause: This is either a system firmware error, or the wrong I/O is connected to the system. Validate the system recipe both firmware and hardware. WBEM EventID: 973. WBEM ProviderName: FPL_IndicationProvider. An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified by the physical location. WBEM EventID: 974. WBEM ProviderName: FPL_IndicationProvider. Predictive Failure in Memory. Probable Cause: You will receive this message if the memory system is observing a lot of corrected ECC errors from a DIMM. The specified DIMM may need to be serviced. Recommended Action: Contact your HP support representative to check the affected hardware. WBEM EventID: 1805. WBEM ProviderName: FPL_IndicationProvider. 60 WBEM Provider Event Tables