HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 25
Memory ECC single-bit ECC error detection failed. Probable Cause: The CEC failed
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
5181 5182 5183 5186 5187 5189 5190 5191 5193 5199 5202 5204 5205 5208 5209 5211 Warning Warning Warning Warning Warning Warning Warning Warning Warning Error Error Warning Warning Error Error Error Memory ECC multiple-bit ECC error signalling failed. Probable Cause: The CEC failed MBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 308. WBEM ProviderName: FPL_IndicationProvider. Memory ECC single-bit data error detection failed. Probable Cause: The CEC failed SBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 309. WBEM ProviderName: FPL_IndicationProvider. Memory ECC single-bit ECC error detection failed. Probable Cause: The CEC failed SBE detection. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 310. WBEM ProviderName: FPL_IndicationProvider. Memory address not found in MBAT. Probable Cause: The address logged in the CEC doesn't map to a memory rank, possibly due to a SFW error or NVM corruption. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 312. WBEM ProviderName: FPL_IndicationProvider. Memory Error Information not cleared. Probable Cause: Software Error or CEC error. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 313. WBEM ProviderName: FPL_IndicationProvider. Couldn't clear memory error logs. Probable Cause: SFW Error or CEC error. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 314. WBEM ProviderName: FPL_IndicationProvider. Memory error clear failed. Probable Cause: SFW error or CEC error. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 315. WBEM ProviderName: FPL_IndicationProvider. DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM is not loaded in order to allow for proper operation of the DIMM specified in the physical location. Recommended Action: Refer to the user's manual for Memory loading instructions. WBEM EventID: 316. WBEM ProviderName: FPL_IndicationProvider. Generic memory firmware error. Probable Cause: Corrupt NVM or System firmware failure. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 317. WBEM ProviderName: FPL_IndicationProvider. Memory interleaving algorithm failed. Probable Cause: Unspecified. WBEM EventID: 2903. WBEM ProviderName: FPL_IndicationProvider. Memory interleave generation failed. Probable Cause: SFW is outdated. Recommended Action: Update SFW. WBEM EventID: 318. WBEM ProviderName: FPL_IndicationProvider. Uncorrectable (multiple-bit) ECC error in DIMM. Probable Cause: Multiple bit error in DIMM. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 2451. WBEM ProviderName: FPL_IndicationProvider. Memory register test failed. Probable Cause: The register within the chipset went bad. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 319. WBEM ProviderName: FPL_IndicationProvider. SPD found no memory DIMMs. Probable Cause: No DIMMs were detected. Recommended Action: Install DIMMs or Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 320. WBEM ProviderName: FPL_IndicationProvider. No memory found. Probable Cause: FW found memory, but it could not find a correctly loaded rank. Recommended Action: Before this event is sent, FW will output which ranks it is deallocating and why. Review the preceding events and refer to the users manual to correct the memory loading. WBEM EventID: 321. WBEM ProviderName: FPL_IndicationProvider. Cannot log memory error because PDT is disabled. Probable Cause: FW found memory errors during selftest, but could not deallocate the page because the PDT is disabled. Recommended Action: Re-enable the PDT by clearing NVM. WBEM EventID: 322. WBEM ProviderName: FPL_IndicationProvider. Platform Events 25