During a Cell On Line Add inconsistent number of cells discovered. Probable Cause

Page 54 highlights

8219 8220 8238 8240 8243 8269 8271 8652 8690 8691 8692 8693 8694 8709 Error Error Error Error Error Warning Error Error Warning Error Warning Warning Warning Error An error was encountered trying to relocate a slave cells registry. Probable Cause: There could be a PD rendezvous error or a processor on the slave cell failed to respond to an interrupt in time. WBEM EventID: 738. WBEM ProviderName: FPL_IndicationProvider. Complex Profile Group C CRC didn't match the expected value. Probable Cause: Push out a new Group C complex profile. WBEM EventID: 2441. WBEM ProviderName: FPL_IndicationProvider. Failure to identify a core cell during Global MCA. Probable Cause: This will lead to a system reset. WBEM EventID: 1034. WBEM ProviderName: FPL_IndicationProvider. Internal firmware programming error in the PMI handler. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 743. WBEM ProviderName: FPL_IndicationProvider. During a Cell On Line Add inconsistent number of cells discovered. Probable Cause: This can be caused by inconsistent profile information. This can also occur when an expected cell did not make the original boot of the partition. Update the complex profile to all the cells with a correct view of the system and try to add the cell again. WBEM EventID: 744. WBEM ProviderName: FPL_IndicationProvider. CPUs of different maximum core frequencies are installed. Probable Cause: CPU's of mixed maximum core frequencies are installed. Recommended Action: Install CPU's with the same speed and cache size. WBEM EventID: 753. WBEM ProviderName: FPL_IndicationProvider. The RVL CC-Togo link initialization workaround (PS221) failed. Probable Cause: Hardware link initialization failed. Recommended Action: Contact HP support. Reset cell. WBEM EventID: 2466. WBEM ProviderName: FPL_IndicationProvider. Internal firmware programming error. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 760. WBEM ProviderName: FPL_IndicationProvider. Initialization of a PCI node in the firmware device tree failed. Probable Cause: The PCI component could not create a device tree node. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. WBEM EventID: 774. WBEM ProviderName: FPL_IndicationProvider. An error was encountered while scanning the PCI bus. Probable Cause: The PCI component experienced an internal system firmware error while scanning the PCI bus. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. WBEM EventID: 775. WBEM ProviderName: FPL_IndicationProvider. An error was encountered initializing the PCI bridge. Probable Cause: The PCI component could not initialize a P2P bridge registers, probably due to faulty hardware. Recommended Action: Reseat or replace the PCI bridge card. WBEM EventID: 776. WBEM ProviderName: FPL_IndicationProvider. An error was encountered initializing the PCI IO map. Probable Cause: The PCI component had insufficient IO port space resources to support the installed PCI cards. Recommended Action: Remove one or more PCI cards to reduce resource requirements; check for faulty cards that are requesting more resources than they need. WBEM EventID: 777. WBEM ProviderName: FPL_IndicationProvider. An error was encountered creating the PCI MMIO map. Probable Cause: The PCI component had insufficient MMIO space to support the installed cards. Recommended Action: Remove one or more PCI cards to reduce the MMIO requirements; check for a PCI card requesting more MMIO resources than it needs. WBEM EventID: 778. WBEM ProviderName: FPL_IndicationProvider. There was an error initializing the SBA node. Probable Cause: An error was while initializing the SBA firmware structures. Recommended Action: Correct any previous errors Invalidate NVM and reset replace the cell board. WBEM EventID: 779. WBEM ProviderName: FPL_IndicationProvider. 54 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

An error was encountered trying to relocate a slave cells registry. Probable Cause:
There could be a PD rendezvous error or a processor on the slave cell failed to respond
to an interrupt in time. WBEM EventID: 738. WBEM ProviderName:
FPL_IndicationProvider.
Error
8219
Complex Profile Group C CRC didn't match the expected value. Probable Cause:
Push out a new Group C complex profile. WBEM EventID: 2441. WBEM
ProviderName: FPL_IndicationProvider.
Error
8220
Failure to identify a core cell during Global MCA. Probable Cause: This will lead to
a system reset. WBEM EventID: 1034. WBEM ProviderName: FPL_IndicationProvider.
Error
8238
Internal firmware programming error in the PMI handler. Probable Cause: Report
the IP to the firmware team. Reset the system. This cannot be worked around in the
field. WBEM EventID: 743. WBEM ProviderName: FPL_IndicationProvider.
Error
8240
During a Cell On Line Add inconsistent number of cells discovered. Probable Cause:
This can be caused by inconsistent profile information. This can also occur when an
expected cell did not make the original boot of the partition. Update the complex
profile to all the cells with a correct view of the system and try to add the cell again.
WBEM EventID: 744. WBEM ProviderName: FPL_IndicationProvider.
Error
8243
CPUs of different maximum core frequencies are installed. Probable Cause: CPU's
of mixed maximum core frequencies are installed. Recommended Action: Install
CPU's with the same speed and cache size. WBEM EventID: 753. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8269
The RVL CC-Togo link initialization workaround (PS221) failed. Probable Cause:
Hardware link initialization failed. Recommended Action: Contact HP support. Reset
cell. WBEM EventID: 2466. WBEM ProviderName: FPL_IndicationProvider.
Error
8271
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
760. WBEM ProviderName: FPL_IndicationProvider.
Error
8652
Initialization of a PCI node in the firmware device tree failed. Probable Cause: The
PCI component could not create a device tree node. Recommended Action: This is
an internal system firmware error. Update system firmware or contact a system
firmware representative. WBEM EventID: 774. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8690
An error was encountered while scanning the PCI bus. Probable Cause: The PCI
component experienced an internal system firmware error while scanning the PCI
bus. Recommended Action: This is an internal system firmware error. Update system
firmware or contact a system firmware representative. WBEM EventID: 775. WBEM
ProviderName: FPL_IndicationProvider.
Error
8691
An error was encountered initializing the PCI bridge. Probable Cause: The PCI
component could not initialize a P2P bridge registers, probably due to faulty
hardware. Recommended Action: Reseat or replace the PCI bridge card. WBEM
EventID: 776. WBEM ProviderName: FPL_IndicationProvider.
Warning
8692
An error was encountered initializing the PCI IO map. Probable Cause: The PCI
component had insufficient IO port space resources to support the installed PCI
cards. Recommended Action: Remove one or more PCI cards to reduce resource
requirements; check for faulty cards that are requesting more resources than they
need. WBEM EventID: 777. WBEM ProviderName: FPL_IndicationProvider.
Warning
8693
An error was encountered creating the PCI MMIO map. Probable Cause: The PCI
component had insufficient MMIO space to support the installed cards. Recommended
Action: Remove one or more PCI cards to reduce the MMIO requirements; check for
a PCI card requesting more MMIO resources than it needs. WBEM EventID: 778.
WBEM ProviderName: FPL_IndicationProvider.
Warning
8694
There was an error initializing the SBA node. Probable Cause: An error was while
initializing the SBA firmware structures. Recommended Action: Correct any previous
errors Invalidate NVM and reset replace the cell board. WBEM EventID: 779. WBEM
ProviderName: FPL_IndicationProvider.
Error
8709
54