HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 102

STBY power and try again. WBEM EventID: 9911. WBEM ProviderName

Page 102 highlights

14519 Error 14520 Warning 14521 Error 14522 Error 14524 Error 14525 Warning 14528 Error 14530 Error 14531 Error 14535 Error 14537 Error System failed power on because one or more auxiliary blades failed to power on. Probable Cause: Power on was denied because there was a failure in the power on sequence. This probably points towards HW or communication synchronization issues. Recommended Action: Reset iLO and try again. If this doesn't work remove STBY power and try again. WBEM EventID: 9911. WBEM ProviderName: FPL_IndicationProvider. A blade failed to power on. Probable Cause: A blade has failed to power on. WBEM EventID: 9912. WBEM ProviderName: FPL_IndicationProvider. System failed to power on because the monarch bladed failed to power on. Probable Cause: A failure on the Monarch has resulted in a failure to power on. As a result the system will be powered off. Recommended Action: Try power on again. Reset iLO and try power on again. Remove STBY power and then try power on again. WBEM EventID: 9913. WBEM ProviderName: FPL_IndicationProvider. A previously powered on blade has lost power. Probable Cause: The blade indicated by the event has unexpectedly lost power. Recommended Action: At the next available opportunity power off the system and power on again. Monitor the blade to make sure this event doesn't happen again. WBEM EventID: 9914. WBEM ProviderName: FPL_IndicationProvider. The system has been powered off due to a power failure. Probable Cause: One or more blades had a power failure. As a result the system control is powering off the entire partition. Recommended Action: Try power on again. If it fails try with a reset to iLO and a removal of STBY power. If system powers back on properly monitor to make sure this doesn't occur again. WBEM EventID: 9915. WBEM ProviderName: FPL_IndicationProvider. The system variables are mismatched. Probable Cause: The contents in the system variables EEPROMs don't match. This indicates that the system variables have been programmed, but they don't match. Recommended Action: Run the SYSSET command to bring the system variables EERPOMs into allignment. WBEM EventID: 9916. WBEM ProviderName: FPL_IndicationProvider. The Power Monitor is in programming mode. Probable Cause: The most likely cause is that the stby power was removed while in the middle of updating the power monitory PIC. In this mode power protection is not enabled. Recommended Action: Update the Power Monitor immediately to return it to its normal state and re-enable power protection features. WBEM EventID: 9917. WBEM ProviderName: FPL_IndicationProvider. Power failed to turn on because there is no SBL (Scalable Blade Link) attached. Probable Cause: Power can not be turned on without an attached SBL. Recommended Action: Attach an appropriate SBL if you want to power on. If an SBL is already attached remove and inspect its pins. Also, inspect the blade side connector. If there are no bent pins and the connector looks ok reseat the SBL and try again. WBEM EventID: 9918. WBEM ProviderName: FPL_IndicationProvider. Power on denied by the OA with an UNKNOWN error code. Probable Cause: iLO was denied power by the OA with an errorcode that was unknown to iLO. Recommended Action: Refer to the recipe documentation to make sure that your OA version is compatible with the iLO FW you are using. Try resetting OA. WBEM EventID: 9919. WBEM ProviderName: FPL_IndicationProvider. A power supply has failed. Physical Location is included in datafield. Probable Cause: A power supply has failed. The connection could be loose or there could be a hardware failure. Recommended Action: Identify the failing supply from the physical location included in the alert. Check connections. If no loose connections are found replace the power supply. WBEM EventID: 9929. WBEM ProviderName: FPL_IndicationProvider. A fan has failed. Probable Cause: A connection may be bad. Otherwise a fan has probably failed. Recommended Action: Identify the Physical Location idicated in the datafield. Check connections and fan health. If connections are ok replace failed fan. WBEM EventID: 9930. WBEM ProviderName: FPL_IndicationProvider. 102 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

System failed power on because one or more auxiliary blades failed to power on.
Probable Cause: Power on was denied because there was a failure in the power on
sequence. This probably points towards HW or communication synchronization
issues. Recommended Action: Reset iLO and try again. If this doesn't work remove
STBY power and try again. WBEM EventID: 9911. WBEM ProviderName:
FPL_IndicationProvider.
Error
14519
A blade failed to power on. Probable Cause: A blade has failed to power on. WBEM
EventID: 9912. WBEM ProviderName: FPL_IndicationProvider.
Warning
14520
System failed to power on because the monarch bladed failed to power on. Probable
Cause: A failure on the Monarch has resulted in a failure to power on. As a result
the system will be powered off. Recommended Action: Try power on again. Reset
iLO and try power on again. Remove STBY power and then try power on again.
WBEM EventID: 9913. WBEM ProviderName: FPL_IndicationProvider.
Error
14521
A previously powered on blade has lost power. Probable Cause: The blade indicated
by the event has unexpectedly lost power. Recommended Action: At the next available
opportunity power off the system and power on again. Monitor the blade to make
sure this event doesn't happen again. WBEM EventID: 9914. WBEM ProviderName:
FPL_IndicationProvider.
Error
14522
The system has been powered off due to a power failure. Probable Cause: One or
more blades had a power failure. As a result the system control is powering off the
entire partition. Recommended Action: Try power on again. If it fails try with a reset
to iLO and a removal of STBY power. If system powers back on properly monitor to
make sure this doesn't occur again. WBEM EventID: 9915. WBEM ProviderName:
FPL_IndicationProvider.
Error
14524
The system variables are mismatched. Probable Cause: The contents in the system
variables EEPROMs don't match. This indicates that the system variables have been
programmed, but they don't match. Recommended Action: Run the SYSSET command
to bring the system variables EERPOMs into allignment. WBEM EventID: 9916.
WBEM ProviderName: FPL_IndicationProvider.
Warning
14525
The Power Monitor is in programming mode. Probable Cause: The most likely cause
is that the stby power was removed while in the middle of updating the power
monitory PIC. In this mode power protection is not enabled. Recommended Action:
Update the Power Monitor immediately to return it to its normal state and re-enable
power protection features. WBEM EventID: 9917. WBEM ProviderName:
FPL_IndicationProvider.
Error
14528
Power failed to turn on because there is no SBL (Scalable Blade Link) attached.
Probable Cause: Power can not be turned on without an attached SBL. Recommended
Action: Attach an appropriate SBL if you want to power on. If an SBL is already
attached remove and inspect its pins. Also, inspect the blade side connector. If there
are no bent pins and the connector looks ok reseat the SBL and try again. WBEM
EventID: 9918. WBEM ProviderName: FPL_IndicationProvider.
Error
14530
Power on denied by the OA with an UNKNOWN error code. Probable Cause: iLO
was denied power by the OA with an errorcode that was unknown to iLO.
Recommended Action: Refer to the recipe documentation to make sure that your OA
version is compatible with the iLO FW you are using. Try resetting OA. WBEM
EventID: 9919. WBEM ProviderName: FPL_IndicationProvider.
Error
14531
A power supply has failed. Physical Location is included in datafield. Probable Cause:
A power supply has failed. The connection could be loose or there could be a hardware
failure. Recommended Action: Identify the failing supply from the physical location
included in the alert. Check connections. If no loose connections are found replace
the power supply. WBEM EventID: 9929. WBEM ProviderName:
FPL_IndicationProvider.
Error
14535
A fan has failed. Probable Cause: A connection may be bad. Otherwise a fan has
probably failed. Recommended Action: Identify the Physical Location idicated in the
datafield. Check connections and fan health. If connections are ok replace failed fan.
WBEM EventID: 9930. WBEM ProviderName: FPL_IndicationProvider.
Error
14537
102
WBEM Provider Event Tables