HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 50

Failure to write data to FRUID EEPROM. Probable Cause: The I2C bus has failed.

Page 50 highlights

7891 7892 7893 7894 7895 7896 7902 7903 7938 7939 7940 7948 Warning Error Warning Error Warning Error Error Error Warning Warning Warning Warning Failure to write data to FRUID EEPROM. Probable Cause: The I2C bus has failed. Look for other entries in the Error Log to confirm this. If there are a lot of entries in this timeframe about I2C failures, analyze errors the errors to see if they are all within a cabinet, or the entire complex. Recommended Action: Each cabinet's Utilities Board (CLU + PM) is responsible for the query over I2C for the FRUID, LPM status, and other information. If there are other entries in the Error Log and they are all within a cabinet, replace the Utilities Board following the Utilities Board Remove + Replace Procedures. WBEM EventID: 701. WBEM ProviderName: FPL_IndicationProvider. CPU fan failed. Probable Cause: The CPU fan identified by the attached physical location has failed. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2904. WBEM ProviderName: FPL_IndicationProvider. CPU fan failing. Probable Cause: The CPU fan identified by the attached physical location is not operating at expected speed. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2905. WBEM ProviderName: FPL_IndicationProvider. CC chip fan failed. Probable Cause: The CC chip fan identified by the attached physical location has failed. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2906. WBEM ProviderName: FPL_IndicationProvider. CC chip fan failing. Probable Cause: The CC chip fan identified by the attached physical location is not operating at expected speed. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2907. WBEM ProviderName: FPL_IndicationProvider. System FW and the PDHC have incompatible shared memory interface revisions. Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named cell was upgraded to a new major revision number and not the other. The major numbers must match when checked by the PDHC or else the cell will not be allowed to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event log. Compare to other cells in the complex, or, if single cell, check firmware revs. available to FWUU. WBEM EventID: 4954. WBEM ProviderName: FPL_IndicationProvider. PDH Controller firmware version is not supported with this version of MP FW. Probable Cause: PDH Controller firmware version is not supported with this version of MP FW. Recommended Action: Update PDHC or MP firmware. WBEM EventID: 707. WBEM ProviderName: FPL_IndicationProvider. Power fault on cell board. Probable Cause: One or more of the DC to DC power converters on the Cell Power Board is displaying a fault condition. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 708. WBEM ProviderName: FPL_IndicationProvider. The CPU Node reported a problem initializing its node in the device tree. Probable Cause: See additional logs in determine why initialize node failed. There could be a hardware or PAL problem. WBEM EventID: 2437. WBEM ProviderName: FPL_IndicationProvider. The ExecuteCommand function failed on a CPU. Probable Cause: Inter-Processor-Interrupts may not be working, or the command may have timed out. This could be a firmware bug or hardware problem. Look for other clues in the event log. WBEM EventID: 710. WBEM ProviderName: FPL_IndicationProvider. A remote CPU is not prepared to receive a command. Probable Cause: The CPU may be stuck waiting for a previous command or may not be healthy. This could also be caused by a system resource contention problem. WBEM EventID: 711. WBEM ProviderName: FPL_IndicationProvider. An error was encountered when executing a PAL_PROC. Probable Cause: PAL was unable to be successfully called. See other event ids to determine if action needs to be taken. WBEM EventID: 614. WBEM ProviderName: FPL_IndicationProvider. 50 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Failure to write data to FRUID EEPROM. Probable Cause: The I2C bus has failed.
Look for other entries in the Error Log to confirm this. If there are a lot of entries in
this timeframe about I2C failures, analyze errors the errors to see if they are all within
a cabinet, or the entire complex. Recommended Action: Each cabinet's Utilities Board
(CLU + PM) is responsible for the query over I2C for the FRUID, LPM status, and
other information. If there are other entries in the Error Log and they are all within
a cabinet, replace the Utilities Board following the Utilities Board Remove + Replace
Procedures. WBEM EventID: 701. WBEM ProviderName: FPL_IndicationProvider.
Warning
7891
CPU fan failed. Probable Cause: The CPU fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem. WBEM EventID: 2904. WBEM ProviderName:
FPL_IndicationProvider.
Error
7892
CPU fan failing. Probable Cause: The CPU fan identified by the attached physical
location is not operating at expected speed. Recommended Action: Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 2905. WBEM
ProviderName: FPL_IndicationProvider.
Warning
7893
CC chip fan failed. Probable Cause: The CC chip fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem. WBEM EventID: 2906. WBEM ProviderName:
FPL_IndicationProvider.
Error
7894
CC chip fan failing. Probable Cause: The CC chip fan identified by the attached
physical location is not operating at expected speed. Recommended Action: Contact
HP Support personnel to troubleshoot problem. WBEM EventID: 2907. WBEM
ProviderName: FPL_IndicationProvider.
Warning
7895
System FW and the PDHC have incompatible shared memory interface revisions.
Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named
cell was upgraded to a new major revision number and not the other. The major
numbers must match when checked by the PDHC or else the cell will not be allowed
to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the
revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event
log. Compare to other cells in the complex, or, if single cell, check firmware revs.
available to FWUU. WBEM EventID: 4954. WBEM ProviderName:
FPL_IndicationProvider.
Error
7896
PDH Controller firmware version is not supported with this version of MP FW.
Probable Cause: PDH Controller firmware version is not supported with this version
of MP FW. Recommended Action: Update PDHC or MP firmware. WBEM EventID:
707. WBEM ProviderName: FPL_IndicationProvider.
Error
7902
Power fault on cell board. Probable Cause: One or more of the DC to DC power
converters on the Cell Power Board is displaying a fault condition. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
708. WBEM ProviderName: FPL_IndicationProvider.
Error
7903
The CPU Node reported a problem initializing its node in the device tree. Probable
Cause: See additional logs in determine why initialize node failed. There could be a
hardware or PAL problem. WBEM EventID: 2437. WBEM ProviderName:
FPL_IndicationProvider.
Warning
7938
The ExecuteCommand function failed on a CPU. Probable Cause:
Inter-Processor-Interrupts may not be working, or the command may have timed
out. This could be a firmware bug or hardware problem. Look for other clues in the
event log. WBEM EventID: 710. WBEM ProviderName: FPL_IndicationProvider.
Warning
7939
A remote CPU is not prepared to receive a command. Probable Cause: The CPU may
be stuck waiting for a previous command or may not be healthy. This could also be
caused by a system resource contention problem. WBEM EventID: 711. WBEM
ProviderName: FPL_IndicationProvider.
Warning
7940
An error was encountered when executing a PAL_PROC. Probable Cause: PAL was
unable to be successfully called. See other event ids to determine if action needs to
be taken. WBEM EventID: 614. WBEM ProviderName: FPL_IndicationProvider.
Warning
7948
50
WBEM Provider Event Tables