HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 46
No Cabinet Start, Insufficient IO Fans. Probable Cause: The number of IO fans required
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
7773 7774 7781 7782 7783 7784 7786 7791 7793 7795 Error Warning Warning Error Error Error Warning Warning Warning Warning Partition being reset due to watchdog timeout expiring. Probable Cause: The watchdog mechanism triggers the MP to reset a partition if its OS becomes unresponsive. An unresponsive OS is detected when the OS fails to refresh the watchdog timer before it expires. PA systems refresh the watchdog timer by emitting an event with data field set to activity level/timeout, and the timeout field specifies the desired timeout. IPF systems refresh the watchdog timer using the IPMI clear watchdog command. The MP emits this event when timer expiration triggers resetting the partition. OS-specific and platform-specific procedures are used to enable/disable the watchdog timer from resetting the partition. See platform and OS documentation for details. Recommended Action: Find out why the partition's OS had hung. The cause could be bad HW that crashed the partition, or in rare cases, a combination of events that caused the OS to be unable to refresh the watchdog timer. Look for other events preceding the timeout for clues to the root cause of the partition being unresponsive. WBEM EventID: 646. WBEM ProviderName: FPL_IndicationProvider. PDHC FW was reset by hardware due to firmware inactivity. Probable Cause: Processor dependent hardware controller (PDHC) Hardware Failed; causing inactivity. Recommended Action: Even though the PDHC will reset itself without interrupting the cell, HP Support personnel should be contacted to troubleshoot the PDH daughtercard and/or cell board as soon as possible. WBEM EventID: 647. WBEM ProviderName: FPL_IndicationProvider. Power Up Aborted, Over Temp. Probable Cause: Reporting Error. Recommended Action: Troubleshoot ambient air sensor/cable/PM3. WBEM EventID: 649. WBEM ProviderName: FPL_IndicationProvider. Too Few Bulk Power Supplies Available. Probable Cause: Too many entities installed in the cabinet for the Power Available. Recommended Action: Remove entities until Power Requirements are met. Add Bulk Power Supplies, if under populated. WBEM EventID: 2435. WBEM ProviderName: FPL_IndicationProvider. No Cabinet Start, Insufficient Blowers. Probable Cause: The number of blowers required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the Cabinet to power up due to an insufficient number of installed blowers. Recommended Action: Install missing Cabinet Blowers. If proper number of blowers are installed, troubleshoot blower presence detection. WBEM EventID: 651. WBEM ProviderName: FPL_IndicationProvider. No Cabinet Start, Insufficient IO Fans. Probable Cause: The number of IO fans required is a hard number. It is not dependent upon the number of entities installed in a Cabinet. The Utilities Subsystem is not allowing the cabinet to power up due to an insufficient number of installed IO fans. Recommended Action: Install missing IO fans, or if proper number installed, troubleshoot IO fan presence detection. WBEM EventID: 652. WBEM ProviderName: FPL_IndicationProvider. AC power to the PDCA was removed. Data Byte 3 specifies PDCA number. Probable Cause: AC Detection and monitoring circuitry failed. Recommended Action: Troubleshoot and replace failed Field Replaceable Units. WBEM EventID: 653. WBEM ProviderName: FPL_IndicationProvider. Cabinet Main Blower Failed. Probable Cause: Cabinet Blower Failed. Recommended Action: Replace failed blower module as soon as possible following the Blower Module Remove and Replace Procedures. WBEM EventID: 654. WBEM ProviderName: FPL_IndicationProvider. 48 Volt Converter Failed. Data Byte 3 specifies PDCA number. Probable Cause: The PDCA identified has failed. This will be evident by many BPS_FAIL codes and probably a AC_DELETED code in the Event Log. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 655. WBEM ProviderName: FPL_IndicationProvider. Fan failed in designated Bulk Power Supply. Probable Cause: Fan failure or fan obstructed. Recommended Action: If fan is obstructed, remove obstruction. If no obstruction, Contact HP Support personnel to troubleshoot problem. WBEM EventID: 657. WBEM ProviderName: FPL_IndicationProvider. 46 WBEM Provider Event Tables