HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 34
Rom revision not equal to FIT revision. Probable Cause: A ROM Rev and FIT Rev
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
5599 5600 5601 5602 5603 5604 5605 5606 5607 5617 5618 5619 5621 5622 5623 Warning Warning Warning Warning Warning Warning Warning Warning Error Warning Warning Warning Error Error Warning Fru Id checksum error. Probable Cause: Error reading the a FRU. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 581. WBEM ProviderName: FPL_IndicationProvider. Fru Id version error. Probable Cause: Error reading a FRU. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 582. WBEM ProviderName: FPL_IndicationProvider. Rom revision not equal to FIT revision. Probable Cause: A ROM Rev and FIT Rev do not match. Recommended Action: Update SFW, if problem persists contact your HP representative for support. WBEM EventID: 583. WBEM ProviderName: FPL_IndicationProvider. ROM revision not equal to Rev block. Probable Cause: A ROM Rev and Rev Block do not match. Recommended Action: Update SFW, if problem persists contact your HP representative for support. WBEM EventID: 584. WBEM ProviderName: FPL_IndicationProvider. Primary Fit bad. Probable Cause: The FIT is bad. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 585. WBEM ProviderName: FPL_IndicationProvider. Secondary Fit bad. Probable Cause: The FIT is bad. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 586. WBEM ProviderName: FPL_IndicationProvider. PAL A execution rom warning. Probable Cause: PAL_A_ROM has generated a warning. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 587. WBEM ProviderName: FPL_IndicationProvider. PAL B execution rom warning. Probable Cause: PAL_B_ROM has generated a warning. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 588. WBEM ProviderName: FPL_IndicationProvider. An error was encountered when firmware tried to update the Group B Profile. Probable Cause: Utilities may be unavailable to update the profiles. Check the connections are reset. WBEM EventID: 1030. WBEM ProviderName: FPL_IndicationProvider. PCI parity error detected. Probable Cause: I/O bus parity error. Recommended Action: Consult the error logs for additional information. Determine and replace the failed I/O device. WBEM EventID: 430. WBEM ProviderName: FPL_IndicationProvider. PCI system error detected. Probable Cause: I/O device failure. Recommended Action: Consult the error logs for additional information. Determine and replace the failed I/O device. WBEM EventID: 431. WBEM ProviderName: FPL_IndicationProvider. I/O host bridge is deconfigured. Probable Cause: See earlier error event. Recommended Action: See earlier error event. WBEM EventID: 432. WBEM ProviderName: FPL_IndicationProvider. Firmware was unable to publish the Partition Profile. Probable Cause: Utilities may be unavailable to update the profiles. Check the connections are reset. WBEM EventID: 1008. WBEM ProviderName: FPL_IndicationProvider. The reporting cell is not configured to be in a PD. Probable Cause: Run parmgr to configure the cell into a PD and reset the PD or add the cell. WBEM EventID: 434. WBEM ProviderName: FPL_IndicationProvider. DIMM thermal loading order warning. Probable Cause: The current DIMM loading order does not follow the guidelines in the user manual. Recommended Action: Rearrange the DIMMs to follow the loading order specified in the Maintenance and Operation Manual. WBEM EventID: 435. WBEM ProviderName: FPL_IndicationProvider. 34 WBEM Provider Event Tables