HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 23

I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended

Page 23 highlights

5137 5138 5139 5140 5141 5142 5143 5144 5145 5146 5147 5148 5149 5150 5152 5155 Warning Warning Warning Warning Warning Warning Warning Warning Warning Warning Warning Warning Warning Warning Error Error Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO subsystem has been exceeded. Recommended Action: The IO config in the system is unsupported. Verify that the IO config installed in the system is one that is supported. If problem persists contact your HP representative for support. WBEM EventID: 277. WBEM ProviderName: FPL_IndicationProvider. PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 278. WBEM ProviderName: FPL_IndicationProvider. PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration. Recommended Action: Remove any unsupported I/O cards. Move the I/O card to another slot. WBEM EventID: 279. WBEM ProviderName: FPL_IndicationProvider. PCI bus unmap unknown error. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 280. WBEM ProviderName: FPL_IndicationProvider. PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended Action: Contact your HP representative to check the I/O host bridge. WBEM EventID: 281. WBEM ProviderName: FPL_IndicationProvider. Power monitor failed to respond. Probable Cause: BMC failure. Recommended Action: Contact your HP representative to check the BMC. WBEM EventID: 282. WBEM ProviderName: FPL_IndicationProvider. I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended Action: Reboot. If problem persists, contact your HP representative to check the I/O controller. WBEM EventID: 283. WBEM ProviderName: FPL_IndicationProvider. I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action: Contact your HP representative to check the I/O chipset. WBEM EventID: 284. WBEM ProviderName: FPL_IndicationProvider. PCI slot has incorrect default power state. Probable Cause: The hot-plug controller has failed. Recommended Action: Contact your HP representative to check the hot-plug slot. WBEM EventID: 285. WBEM ProviderName: FPL_IndicationProvider. PCI slot power on error. Probable Cause: The I/O card is damaged or improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 286. WBEM ProviderName: FPL_IndicationProvider. PCI slot's standby power failed. Probable Cause: I/O slot failure. Recommended Action: Reseat IO card. Replace IO card. If problem persists, contact your HP representative to check the I/O slot. WBEM EventID: 287. WBEM ProviderName: FPL_IndicationProvider. Found invalid PCIXCAP value. Probable Cause: The I/O card is damaged or improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 288. WBEM ProviderName: FPL_IndicationProvider. Unsupported rope frequency. Probable Cause: Internal firmware error. Recommended Action: Contact your HP representative to check the firmware. WBEM EventID: 289. WBEM ProviderName: FPL_IndicationProvider. Unsupported host bridge type. Probable Cause: Firmware needs to be updated. An incorrect I/O backplane is installed. Recommended Action: Contact your HP representative to check the firmware and the I/O backplane. WBEM EventID: 290. WBEM ProviderName: FPL_IndicationProvider. Machine Check initiated. Probable Cause: A Machine Check has occurred. Recommended Action: Analyze cause of Machine Check using diag's and EFI tools. WBEM EventID: 292. WBEM ProviderName: FPL_IndicationProvider. Error in temporary mdt area. Probable Cause: The memory area where the MDT is supposed to be built has an error in it, so the MDT cannot be built there. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider. Platform Events 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Insufficient power to turn on PCI slot. Probable Cause: The power budget for the IO
subsystem has been exceeded. Recommended Action: The IO config in the system
is unsupported. Verify that the IO config installed in the system is one that is
supported. If problem persists contact your HP representative for support. WBEM
EventID: 277. WBEM ProviderName: FPL_IndicationProvider.
Warning
5137
PCI bus walk unknown error. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 278.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5138
PCI bus walk resources exceeded. Probable Cause: Unsupported I/O configuration.
Recommended Action: Remove any unsupported I/O cards. Move the I/O card to
another slot. WBEM EventID: 279. WBEM ProviderName: FPL_IndicationProvider.
Warning
5139
PCI bus unmap unknown error. Probable Cause: Internal firmware error.
Recommended Action: Contact your HP representative to check the firmware. WBEM
EventID: 280. WBEM ProviderName: FPL_IndicationProvider.
Warning
5140
PCIXCAP sampling error. Probable Cause: I/O host bridge failure. Recommended
Action: Contact your HP representative to check the I/O host bridge. WBEM EventID:
281. WBEM ProviderName: FPL_IndicationProvider.
Warning
5141
Power monitor failed to respond. Probable Cause: BMC failure. Recommended
Action: Contact your HP representative to check the BMC. WBEM EventID: 282.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5142
I/O rope reset failed to complete. Probable Cause: I/O CEC failure. Recommended
Action: Reboot. If problem persists, contact your HP representative to check the I/O
controller. WBEM EventID: 283. WBEM ProviderName: FPL_IndicationProvider.
Warning
5143
I/O SBA clear error failed. Probable Cause: I/O chipset failure. Recommended Action:
Contact your HP representative to check the I/O chipset. WBEM EventID: 284. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5144
PCI slot has incorrect default power state. Probable Cause: The hot-plug controller
has failed. Recommended Action: Contact your HP representative to check the
hot-plug slot. WBEM EventID: 285. WBEM ProviderName: FPL_IndicationProvider.
Warning
5145
PCI slot power on error. Probable Cause: The I/O card is damaged or improperly
inserted. Recommended Action: Replace or reseat the I/O card. WBEM EventID: 286.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5146
PCI slot's standby power failed. Probable Cause: I/O slot failure. Recommended
Action: Reseat IO card. Replace IO card. If problem persists, contact your HP
representative to check the I/O slot. WBEM EventID: 287. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5147
Found invalid PCIXCAP value. Probable Cause: The I/O card is damaged or
improperly inserted. Recommended Action: Replace or reseat the I/O card. WBEM
EventID: 288. WBEM ProviderName: FPL_IndicationProvider.
Warning
5148
Unsupported rope frequency. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 289.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5149
Unsupported host bridge type. Probable Cause: Firmware needs to be updated. An
incorrect I/O backplane is installed. Recommended Action: Contact your HP
representative to check the firmware and the I/O backplane. WBEM EventID: 290.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5150
Machine Check initiated. Probable Cause: A Machine Check has occurred.
Recommended Action: Analyze cause of Machine Check using diag's and EFI tools.
WBEM EventID: 292. WBEM ProviderName: FPL_IndicationProvider.
Error
5152
Error in temporary mdt area. Probable Cause: The memory area where the MDT is
supposed to be built has an error in it, so the MDT cannot be built there.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider.
Error
5155
Platform Events
23