HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 43
Table #2, Event ID numbers 7, 000 through 14
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
5853 5896 6002 6074 6146 6180 6730 6795 Warning Error Error Error Warning Warning Error Warning OS dump, error writing image area to disk (E055). Probable Cause: panic path forward progress. WBEM EventID: 556. WBEM ProviderName: FPL_IndicationProvider. Coherency controller (CC) registers indicate a Deadlock Recovery Reset. Probable Cause: Coherency controller (CC) resources are deadlocked and the CC is resetting the cell. Recommended Action: Analyze the Deadlock Recovery logs (like MCA logs) to determine the cause of the failure. WBEM EventID: 1019. WBEM ProviderName: FPL_IndicationProvider. A memory address parity error has been detected. The physical location can be located in the data field. Probable Cause: Poorly seated memory extender. Recommended Action: Reseat memory extender. WBEM EventID: 5268. WBEM ProviderName: FPL_IndicationProvider. A DIMM loading order error has occurred. Probable Cause: Incorrect loading of the DIMMs on the cell. Recommended Action: Install the DIMMs in the correct order. DIMMs are installed in ranks of DIMMs , starting with DIMM 0A, 0B, etc. Subsequent ranks are loaded in ascending order , i.e., rank 1, 2, 3, 4, 5, 6 and 7. WBEM EventID: 590. WBEM ProviderName: FPL_IndicationProvider. Refresh Control Error Timeout. Probable Cause: At start of memory refresh, timing out waiting for ready bit to be set. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 591. WBEM ProviderName: FPL_IndicationProvider. memory extender/baseboard FRU mismatch. Probable Cause: Memory extender and baseboard are incompatible. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 592. WBEM ProviderName: FPL_IndicationProvider. Fabric topology mismatch with XBCs in complex. Probable Cause: There is a fabric topology mismatch with XBC in complex. Recommended Action: Contact HP Support personnel to analyze the cell, XBC flex cables, system backplane. WBEM EventID: 593. WBEM ProviderName: FPL_IndicationProvider. An invalid XBC to XBC port was found. Probable Cause: Loss of Lockstep. Recommended Action: Reset. WBEM EventID: 594. WBEM ProviderName: FPL_IndicationProvider. Table #2 - Event ID numbers 7,000 through 14,910 Event ID 7652 Event Severity Warning 7653 Error 7655 Warning 7657 Error Event Description Could not get neighbor information. Probable Cause: Defective XBC link Defective XBC. Recommended Action: Check XBC link connections Reset the system backplane Contact HP Support personnel to troubleshoot problem. WBEM EventID: 595. WBEM ProviderName: FPL_IndicationProvider. The XBC's routing state was marked as in ERROR. Probable Cause: Another cell already attempted routing for the XBC and found an error. Recommended Action: Check for hardware failure: flex cables, crossbar chip, etc. WBEM EventID: 596. WBEM ProviderName: FPL_IndicationProvider. It indicates that there is no NVM error space left for logging an Error Event. Probable Cause: The error event will not be logged. WBEM EventID: 597. WBEM ProviderName: FPL_IndicationProvider. An XBC port found to have an unexpected error. Probable Cause: A port was landmined so it had to be routed around. Recommended Action: Check flex cables. WBEM EventID: 598. WBEM ProviderName: FPL_IndicationProvider. Platform Events 43