HP Integrity rx2800 HP Insight Management WBEM Provider Events Reference Guide - Page 69
unable to release a XBC semaphore. Recommended Action: Collect IPMI Event Logs.
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
10529 Warning 10530 Warning 10532 Warning 10534 Warning 10535 Warning 10558 Warning 10559 Warning 10560 Warning 10561 Warning 10564 Warning 10565 Warning 10566 Warning 10567 Warning 10568 Warning Failed to get the address of the XBC Global Semaphore. Probable Cause: Failed to get a fabric address. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4855. WBEM ProviderName: FPL_IndicationProvider. Failed to write the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore. Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. WBEM EventID: 4856. WBEM ProviderName: FPL_IndicationProvider. Failed to release the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore. Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. WBEM EventID: 4857. WBEM ProviderName: FPL_IndicationProvider. Fabric phases have been executed in an invalid order. Probable Cause: System firmware failed a validation check on its routing progress. Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative. WBEM EventID: 4858. WBEM ProviderName: FPL_IndicationProvider. Fabric phases have been executed in an invalid order. Data field indicates the expected phase. Probable Cause: System firmware failed a validation check on its routing progress. Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative. WBEM EventID: 4859. WBEM ProviderName: FPL_IndicationProvider. Failed to get an address when opening XBC to XBC links. Probable Cause: Failed to get a fabric address. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4885. WBEM ProviderName: FPL_IndicationProvider. Failed to open a fabric link. Probable Cause: System Firmware was unable to open the crossbar link. Recommended Action: Collect IPMI Event Logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4895. WBEM ProviderName: FPL_IndicationProvider. Error when writing the XBC return route. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4897. WBEM ProviderName: FPL_IndicationProvider. Error enabling the XBC return route. Probable Cause: write to XBC failed. Recommended Action: Contact HP Support personnel to check the XBC. WBEM EventID: 4896. WBEM ProviderName: FPL_IndicationProvider. Failed to disperse the routes across links. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. WBEM EventID: 4894. WBEM ProviderName: FPL_IndicationProvider. Error setting up XBC-XBC link for routing across it. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. WBEM EventID: 4899. WBEM ProviderName: FPL_IndicationProvider. Error while routing the remote side of a route. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. WBEM EventID: 4898. WBEM ProviderName: FPL_IndicationProvider. Error getting address while routing the remote XBC. Probable Cause: Failed to get a fabric address. Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4886. WBEM ProviderName: FPL_IndicationProvider. Error getting the neighbor info. Probable Cause: XBC register read failure. Recommended Action: Contact HP Support personnel to analyze the crossbar chip. WBEM EventID: 4887. WBEM ProviderName: FPL_IndicationProvider. Platform Events 69